POWER MONITORING FUNCTIONS
2003 Dec 8     
54
Table 7-1: Brownout Options
POWER-ON DETECTION
The Power-On Detect has a function similar to the  Brownout Detect, but is designed to work as power initially comes up, before 
the power supply voltage reaches a level where the  Brownout Detect can function. The POF flag (RSTSRC.4) is set to indicate 
an initial power-on condition. The POF flag will remain set until cleared by software by writing ’0’ to the bit. Note that if BOE 
(UCFG1.5) is programmed, BOF (RSTSRC.5) will be set when POF is set. If BOE is unprogrammed, BOF is meaningless.
POWER REDUCTION MODES
The P89LPC906/907/908 supports three different power reduction modes as determined by SFR bits PCON.1-0 (see Table ):
BOE 
(UCFG1.5)
PMOD1-0 
(PCON.1-0)
BOPD 
(PCON.5)
BOI 
(PCON.4)
EBO 
(IEN0.5)
EA 
(IEN0.7)
Description
0  (erased)
XX
X
X
X
X
Brownout disabled. V
DD
 operating range is 2.4V-3.6V.
1 (programmed)
11
(total power 
down)
X
X
X
X
≠ 11
(any mode 
other than 
total power 
down)
1
(brownout 
detect 
powered 
down)
X
X
X
Brownout disabled. V
DD
 operating range is 2.4V-3.6V. 
However, BOPD is default to ’0’ upon power-up.
0
(brownout 
detect 
active)
0
(brownout 
detect 
generates 
reset)
X
X
Brownout reset enabled. V
DD
 operating range is 2.7V-
3.6V. Upon a brownout reset, BOF (RSTSRC.5) will be 
set to indicate the reset source. BOF can be cleared by 
writing ’0’ to the bit.
1
(brownout 
detect 
generates 
an 
interrupt)
1
(enable 
brownout 
interrupt)
1
(global 
interrupt 
enable)
Brownout interrupt enabled. V
DD
 operating range is 2.7V-
3.6V. Upon a brownout interrupt, BOF (RSTSRC.5) will 
be set. BOF can be cleared by writing ’0’ to the bit.
0
X
Both brownout reset and interrupt disabled. V
DD
 
operating range is 2.4V-3.6V. However, BOF 
(RSTSRC.5) will be set when V
DD
 falls to the  Brownout 
Detection trip point. BOF can be cleared by writing ’0’ to 
the bit.
X
0