Philips P89LPC907 用户手册

下载
页码 110
Philips Semiconductors
User’s Manual - Preliminary -
P89LPC906/907/908
POWER MONITORING FUNCTIONS
2003 Dec 8     
56
Figure 7-1: Power Control Register (PCON)
PCON
Address: 87h
Not bit addressable
Reset Source(s): Any reset
Reset Value:
00000000B 
BIT
SYMBOL
FUNCTION
PCON.7
SMOD1
Double Baud Rate bit for the serial port (UART) when Timer 1 is used as the baud rate 
source. When 1, the Timer 1 overflow rate is supplied to the UART. When 0, the Timer 1 
overflow rate is divided by 2 before being supplied to the UART. P89LPC907
P89LPC908(See Figure 8-2).
PCON.6
SMOD0
Framing Error Location (P89LPC908):
-When 0, bit 7 of SCON is accessed as SM0 for the UART.
-When 1, bit 7 of SCON is accessed as the framing error status (FE) for the UART.
This bit also determines the location of the UART receiver interrupt RI  (see description 
on RI in Figure 8-3).
PCON.5
BOPD
Brownout Detect Power down. When 1, Brownout Detect is powered down and therefore 
disabled. When 0, Brownout Detect is enabled. (Note: BOPD must be ’0’ before any 
programming or erasing commands can be issued. Otherwise these commands will be 
aborted.)
PCON.4
BOI
Brownout Detect Interrupt Enable. When 1, Brownout Detection will generate a interrupt . 
When 0, Brownout Detection will cause a reset.
PCON.3
GF1
General Purpose Flag 1. May be read or written by user software, but has no effect on 
operation.
PCON.2
GF0
General Purpose Flag 0. May be read or written by user software, but has no effect on 
operation.
PCON.1-0
PMOD1-PMOD0
Power Reduction Mode (see section "Power Reduction Modes").
7
6
5
4
3
2
1
0
SMOD1 SMOD0
BOPD
BOI
GF1
GF0
PMOD1 PMOD0