ACCESSORIES
In the U.S.A., Input BTU shall be derated 4%(1 orifice
size) per 1000ft, for above 2000ft.. In Canada, input BTU
shall be derated 10% (2 orifice size) at altitudes from
2000ft.to 4500ft..
TROUBLESHOOTING
POSSIBLE CAUSE
1.
Air in gas lines.
2.
Inlet gas pressure is too low.
3.
Gas supply turned off.
4.
Air passageway on heater blocked.
5.
Burner orifice clogged.
6.
Control knob not in ING/ON position.
7.
Control knob not fully pressed in while
         in ING/ON position.
1.
Ignitor electrode positioned wrong.
2.
Ignitor broken.
3.
Broken ignitor cable.
4.
Ignitor electrode not connected to ignitor cable.
1.
Damaged thermocouple.
2.
Thermocouple electrode corrosion.
3.
Damaged control valve.
4.
Control knob not pressed long enough.
5.
Thermocouple connection loose at control valve.
6.
Pilot flame not touching thermocouple.
When ignitor buttons
pressed in, there is no
spark at safety Pilot.
OBSERVED PROBLEM
Burner does not light
Burner fire does not last.
REMEDY
1.
Continue holding down control knob.
Repeat igniting operation until air is
removed.
2.
Check gas pressure.
3.
Fully open gas supply.
4.
Check air passageway.
5.
Clean burner.
6.
Turn control knob to ING/ON position.
7.
Press down control knob.
1.
Reposition ignitor.
2.
Replace pilot
3.
Replace ignitor cable.
4.
Connect electrode to ignitor cable.
1.Replace thermocouple.
2.
Clean thermocouple electrode.
3.
Replace control valve.
4.
After pilot lights, keep control knob
pressed in for 30 seconds.
5.
Hand tighten connection or replace
thermocouple.
6.
Contact qualified service man.
HIGH ALTITUDE DERATE
Purchase the accessories from your local dealer or
Parts Central. If they cannot supply these accessories
call PRO-COM’s Sales Department at 1-877-886-5989
for referral information. You can also write to the ad-
dress listed on the back page of this manual.
SPECIFICATIONS
Model
                 L600HYLA/B
                        PN750HYLA/B
Btu (LP/NG)
          60.000                                              75.000
Gas Type
                LP                                                     NG
Ignition
                 Piezo
                                 Piezo
Inlet Gas Pressure* (In. of water)
        Maximum
      14”
                                        10.5”
        Minimum
      11”
                                         5.5”
Dimensions, Inches     (H x W x D)
       Stove
            17 3/4” x22 7/8”x18 1/8”                  17 3/4” x22 7/8”x18 1/8”
       Carton
        15” x25 ”x20 1/4”                              15” x25 ”x20 1/4”
Weight, Lbs
   Stove
                    32/33
                                         32/ 33
   Shipping Weight              55/58
                                         55/ 58
* For purpose of shipment adjustment.
Minimum clearances:   Bottom:
(This appliance may not be place on any combustible materials)
                                         Top:                 8 FT.  (2.4m)
                      Side /walls (around): 48 inch (1220mm)