Procom PL600HYLA 用户手册

下载
页码 13
8
LIGHTING INSTRUCTIONS
      
WARNING:FOR YOUR SAFETY READ
BEFOR LIGHTING
1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
3. Press in and turn control knob clockwise
           
90
degree to the OFF position.
4. Wait five (5) minutes to clear out any gas. Then
smell for gas around log set and near floor. If you
smell gas, STOP! Follow the safety information
above. If you don’t smell gas, go on to the next step.
5. Turn control knob counterclockwise  
         
90
degree to the PILOT position and press in. Keep con-
trol knob pressed in for five(5) seconds.
Note: You may be running this log set for first time
after hooking up to gas supply. If so, the control
knob may need to be pressed in for 30 seconds.
This will allow air to bleed from the gas system.
6. With control knob pressed in, push down and re-
lease ignitor button. This will light the pilot. The pi-
lot is attached to the side of the front burner. If
needed, keep pressing ignitor button until pilot
lights.
NOTE: If pilot does not stay lit, contact a qualified
service person or PRO-COM’s 800# on the back
of this  manual. Until repairs are made,  light pilot
with the piezo.
7. Keep control knob pressed in for 30 seconds after
lighting pilot. After 30 seconds, release control knob.
Note: 
If pilot goes out, repeat steps 3 through 7.
  
If control knob does not pop up when released, con-
tact a qualified service person or PRO-COM’s 800#
on the back of this manual.
8. Turn control knob counterclockwise
           
90
degree to the ON position. Burner should light. If
burner does not light, call a qualified service person
or PRO-COM’s 800# on the back of this manual.
                      Fig12  The operationg board
MAINTENANCE AND STORAGE
1. Storage of an appliance indoors is permissible
only if the gas supply system is disconnected and
removed from the appliance. .
2. Have the heater inspected by qualified service
man before each use or at least annually.
3. Check the
 
POL fitting for any damage before each
use and replace if any damage is found.
4. Spiders and insects can nest and live in outdoor
appliances, especially in the burners and orifices.
This will interrupt the normal flow of LP gas to
the heater and can be a very dangerous situation.
Inspect for insect infiltration of burner/orifice when
one of the following occurs:
A. The smell of gas along with predominating yel-
low tipping of the burner flames.
B. Heater can not reach desired temperature.
C. Uneven burner flow.
D. Burner makes popping noises during normal
use or shutdown.
5. Adopt rainproof cover (provided with the heater)
    to avoid rust of heater when not in use.
      
WARNING:
 
If you do not follow these in-
structions exactly, a fire or explosion may
result causing property damage, personal in-
jury or loss of life.
TO TURN OFF GAS TO APPLIANCE
Shutting Off Appliance
1. Turn control knob clockwise                90 degrees to
the PILOT position.
2. Press in and turn control knob          clockwise 90
degrees to OFF position.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise                 90 degrees to the
PILOT position.