Mitsubishi Electronics E60 用户手册

下载
页码 415
6. 
AXIS SPECIFICATIONS PARAMETERS 
6.1 
Axis Specifications Parameters 
II - 83 
 
Items 
Details 
Setting range (unit) 
 
 
 
(Continued from the previous page) 
 
<Combination of acceleration and deceleration 
patterns and bit patterns>  
 
 
R1 > R3 when both R1 and R3 contain 1. 
Rapid traverse R3(bit3) -(bit2) R1(bit1) LR(bit0) 
Cutting feed 
C3(bit7) -(bit6) C1(bit5) LC(bit4) 
Step  0 0 0  0 
Linear 
acceleration/
deceleration
0 0 0  1 
Primary 
delay 
0 0 1  0 
Exponential 
acceleration 
and linear 
deceleration
1 0 0  0 
Acceleration/deceleration types 
Acceleration/
deceleration 
by software
1 1 1  1 
 
   
 
 
<Stroke end stop types> 
 
Type OT2 
OT3 
Linear deceleration 
Position loop step stop 
Speed loop step stop 
Position loop step stop 
 
Deceleration by G0t1 
OT1 
Deceleration by 2 
× G0t1 
 
 
G0t1
Speed
Stroke end signal
Time
2
G 0 t 1 (OT1=1,OT2=OT3=0)
G 0 t 1 (OT1=OT2=OT3=0)
 
 
OT1 is valid under the following conditions (valid for dog 
type zero point return): 
    Stop type: Linear deceleration 
    Acceleration mode: Exponential 
    Deceleration mode: Linear