Troubleshooting 
Label all wires prior to disconnection 
when servicing controls.  Wiring errors 
can cause improper and dangerous 
operation.  Always disconnect power 
to the water heater before servicing. 
 
Failure to comply could result in severe 
personal injury, death, or substantial 
property damage.
Never jumper (bypass) any device except 
for momentary testing as outlined in the 
Troubleshooting chart.  Severe personal 
injury, death, or substantial property 
damage can result.
Before troubleshooting:
1.  Have the following items:
a. 
Voltmeter  that  can  check  120  VAC,  24  VAC,  and            
 12 
VDC.
b. Continuity 
checker.
c. Contact 
thermometer.
2.  Check  for  120  VAC  (minimum  102  VAC  to  maximum       
132 VAC) to water heater.
3.  Make sure the tank is calling for heat.
4.  Make sure all external limit controls are installed and 
operating.
Check the following:
1.  Wire connectors to control module and connection 
board are securely plugged in.
2. Gas 
pressures:
• Maximum: 14 inches w.c. (natural and LP) with no 
  flow (lockup) or with water heater on
• Minimum: 4 inches w.c. (natural), 8 inches w.c. (LP) 
  with gas flowing (verify during water heater startup)
Check control module fuses
ALWAYS check control module fuses 
before replacing control module or any 
major components (blower, etc.).  If one 
of these fuses is blown, it can prevent the 
control module or other components from 
operating.
1.  Turn OFF power to the water heater at the external 
 disconnect 
switch.
2.  Remove top access cover.
3.  Remove the control module cover.
4.  Inspect fuses F2, F3, F4, and F5, see FIG. 12-1 below.
F4 - 3.15 AMP FUSE
BLOWER
F3 - 1.25 AMP FUSE
MAIN BOARD
F5 - 5 AMP FUSE
PUMPS
F2 - 3.15 AMP FUSE
24V SUPPLY
Figure 12-1 Control Module Fuses
5.  The water heater is shipped with three (3) spare fuses in a 
plastic bag attached to the control module cover.
6.  If necessary, replace open fuse (F3 is 1.25 amps, F2 and F4 
are 3.15 amps, and F5 is 5 amps).
Note:  Fuses F2 - F5 are all slow blow fuses.
Do not jumper fuse or replace with any fuse 
except as specified.  Failure to comply could 
result in severe personal injury, death, or 
substantial property damage.
7.  Install control module cover and top access cover after fuse 
inspection.
8.  Restore power to the water heater at the external 
disconnect switch and verify water heater operation 
(Section 9 - Start-up) after completing water heater service.
 WARNING
 WARNING
 NOTICE
 WARNING
       