WASTE INLET LINE
Connect.the.disposer.outlet.flange.as.close.as..
possible.and.with.as.few.as.possible.90°.elbows.to..
the.Waste.Xpress.inlet.
NOTE: The maximum allowable distance between the
disposer outlet flange and the Waste Xpress inlet is  
10 feet with a maximum of four (4) 90° elbows.
1..Connect.the.disposer.outlet.to.the.Waste.Xpress..
. inlet.using.2".NPT.plumbing..3.HP.will.require.3"..
. outlet.adapter..The.run.between.the.disposer.and..
. Waste.Xpress.should.have.1/4".slope.per.foot.and..
. must.comply.with.all.local.codes.
NOTE: All horizontal runs should be as short as 
possible (not to exceed 10 ft.), with an approximate  
fall of 1/4" per foot.
TO REVERSE AUGER SCREEN:
A..Holding.both.handles.remove.discharge.chute..
of.the.Waste.Xpress.by.tilting.it.upward..
(see.Figure.13).
B..Remove.auger-bearing.bracket.by.sliding.the.two
captive.fasteners.inward.and.then.pull
bracket.upward.(see.Figure.14).
C..Lift.auger.and.screen.up.and.then.out..
(see.Figure.14).
D..Remove.auger.from.screen.by.lifting.up..
(see.Figure.15).
E..Remove.four.nuts.and.washers.holding.the.top..
portion.of.the.auger.screen.to.the.bottom.portion..
(see.Figure.16).
F..Rotate.bottom.portion.of.the.auger.screen.180°.
and.secure.to.top.portion.with.four.nuts.and..
washers.(see.Figure.17).
TO CHANGE WASTE INLET SIDE ON  
WASTE XPRESS:
A..Remove.four.screws.holding.inlet.fitting.and..
gasket.in.position.(see.Figure.18).
B..Remove.four.screws.holding.the.cap.and.gasket.in.
position.(see.Figure.18).
C..Install.gaskets,.cap.and.inlet.fitting.on.reverse.side.
and.secure.with.appropriate.screws.
Figure 15.
Figure 16.
Figure 17.
Plumbing Connections
Nuts.&..
Washer.(4)
Auger
Screen
Inlet
Figure 18.
Waste.
Outlet
Waste.
Inlet
PROPERTY DAMAGE
Water.connections.must.comply.with.all.local.
plumbing.codes.