The.WX-101A.Control.Center.is.UL
®
.approved.for.use.
with.InSinkErator.Waste.Xpress.food.waste.reduction.
systems..The.control.center.operates.the.disposer.and.
Waste.Xpress..Its.main.functions.are:
•.To.start.and.stop.the.disposer/Waste.Xpress.system.
•.To.reverse.the.direction.of.the.disposer.motor..
. automatically.upon.restart.
•.To.start.the.water.flow.to.the.disposer.
•.To.allow.water.flow.for.several.minutes.to.flush.the..
. drain.line.after.the.disposer.is.turned.off.
Model
Part No.
Voltage
Phase
WX-101A-3
14479B
208/230V
3
WX-101A-4
14479C
380/460V
3
FEATURES
SINGLE.BUTTON.OPERATION
Disposer.and.Waste.Xpress.are.controlled.by.simple
ON/OFF.button.operation.
AUTOMATIC.REVERSE
The.disposer.motor.will.reverse.its.direction.of..
rotation.automatically.upon.restart..To.avoid.motor..
damage,.a.delay.feature.prevents.reversing.until..
the.post.flush.is.complete.
WATER.SHUTOFF.DELAY.(POST.FLUSH)
After.the.motor.is.turned.off,.the.water.continues.to
flow.for.up.to.10.minutes..The.length.of.this.post.flush
is.controlled.by.the.water.shutoff.delay.timer..The.post
flush.helps.ensure.that.ground.food.waste.is.flushed
out.of.the.drain.line.
AUTOMATIC.TIMED.DISPOSER.SHUTOFF
This.water.saving.feature.allows.the.system.to.run.for
10.minutes.before.it.automatically.shuts.off.and.must
be.manually.restarted.
LINE.DISCONNECT.SWITCH
The.switch.on.the.front.panel.of.the.control.center
disconnects.the.line.voltage..It.interlocks.with.the.front
cover.so.that.the.cover.cannot.be.opened.unless.the
switch.is.in.the.off.position.
LOW.VOLTAGE.CONTROL
Control.operates.on.a.24.V.solid.state.control.circuit.
ENCLOSURE
Stainless.steel.NEMA.4.construction.
WX.TIMER.HOT.WATER.SPRAY.ADJUSTABLE
Factory.set.for.2.minutes.off.10.second.on.controls.hot.
water.spray.for.cleaning.of.screen.
Table 1.  Electrical Specifications
WX-101A Control Features/Mounting Control Center
15-1/8"
(384.2 mm)
14"
(355.6 mm)
15-3/4"
(400.1 mm)
9-7/8"
(250.8 mm)
8-1/4"
(209.6 mm)
5-1/4"
(133.4 mm)
5-5/16"
(134.9 mm)
6-3/4"
(171.5 mm)
1" 
(25.4 mm)
MOUNTING THE CONTROL CENTER
Use.the.flanges.at.the.back.of.the.control.center..
enclosure.and.only.mount.panel.in.the.upright.vertical.
position.(door.hinge.is.on.the.left)..See.Figure.4.
Locate.control.center.within.sight.of.disposer.per..
local.codes.
If.box.is.mounted.to.the.sink.table,.recess.the.box.so.
that.the.buttons.do.not.extend.beyond.the.table’s.edge.
(see.Figure.4).
Figure 4. Control Center Dimensions
ELECTRICAL SHOCK
.•.Ensure.that.Waste.Xpress.voltage.and.phase.
match.that.of.the.electrical.supply,.control.center..
&.disposer..Check.nameplate.for.specification.
.•.Electrical.connections.should.be.made.by.a..
qualified.electrician.and.should.comply.with.all..
local.codes.
.•.Turn.off.electrical.supply.to.Waste.Xpress,..
control.center.&.disposer.before.attempting.to.
work.on.it..Test.with.a.volt.meter.or.circuit.tester..
to.ensure.that.power.is.off.
.•.Do.not.operate.unit.with.panels.removed.
.•.All.components.(disposer,.WX,.control.center..
and.solenoids).must.be.carefully.and.permanently.
grounded.
.•.A.properly.fused.disconnect.must.be.installed.at.
Waste.Xpress,.control.center.&.disposer.electrical.
supply.source.
.•.Use.only.NEMA.4.watertight.electrical.connectors.
when.connecting.to.junction.box.