Mounting the Control Center/Plumbing Connections
MOUNTING THE CONTROL CENTER
Use the flanges at the back of the control center  
enclosure and only mount panel in the upright vertical  
position (door hinge is on the left). See Figure 1.
Locate control center within sight of disposer per local 
codes. Locate any remote control station within sight of 
disposer per local codes.
If box is mounted to the sink table, recess the box so 
that the buttons do not extend beyond the table’s edge.
PLUMBING CONNECTIONS 
Two solenoid valves with flow control valves  
pre-installed (1 GPM and 7 GPM) are packed with the 
control center. The syphon breaker is supplied with all 
complete disposer packages (packed separately).
The solenoid valve is supplied with a 24 V coil. Make 
certain that the valves are plumbed according to the 
water flow direction arrows marked on the valve or the 
valves will not function properly.
The flow control valve regulates all water flowing into 
the disposer. This conserves water and prevents  
overloading. Check direction of water flow arrows.
Syphon breaker must be installed above the sink flood 
plane 
per local plumbing codes. Check direction of 
water flow arrows.
Figure 2.  Typical Installation Diagram
Figure 1. Control Center Dimensions
NOTE: The AS-101K control center requires the use  
of two solenoid valves and two flow control valves.  
Figure 2 shows the proper installation for an  
AS-101K control center.
Sink Installation
Trough Installation
9-7/8"
(250.8 mm)
8-1/4"
(209.6 mm)
15-3/4"
(400.1 mm)
5-5/16"
(134.9 mm)
15-1/8"
(384.2 mm)
14"
(355.6 mm)
1"
(25.4 mm)
6-3/4"
(171.5 mm)