Figure 6 - Lineal Gain
LINEAL GAIN
PART NO.
DESCRIPTION
GAIN
Georgian
Fireplace
66 
1
/
2
"
12-12DM
12-12HT
Pipe Section
10 
5
/
8
"
18-12DM
18-12HT
Pipe Section
16 
5
/
8
"
24-12DM
24-12HT
Pipe Section
23 
5
/
8
"
36-12DM
36-12HT
Pipe Section
34 
5
/
8
"
48-12DM
48-12HT
Pipe Section
46 
5
/
8
"
RLT-12D
RLT-12HT Round Termination
3
/
4
"*
STL-12D Square Chase-Top 
with Slip Section 7" to 15"*
* The lineal gain for the terminations is mea-
sured to the flue gas outlet height.
Hemmed 
End
12 
3
/
8
Stainless 
Inner Pipe
15" Galvanized 
Outer Pipe
ASSEMBLY AND INSTALLATION OF 
DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists of a 
galvanized outer pipe, a stainless steel inner flue 
pipe and a wire spacer. Pipe sections must be 
assembled independently as chimney is installed. 
When connecting chimney directly to fireplace, 
the inner flue pipe section must be installed first 
with lanced side up. The outer pipe section can 
then be installed over the flue pipe section with 
hemmed end up. Press down on each pipe sec-
tion until lances securely engage hem on fireplace 
starter. The wire will assure the proper spacing 
between inner and outer pipe sections.
Continue  to  assemble  chimney  sections  as 
outlined above, making sure that both inner and 
outer pipe sections are locked together. When 
installing double wall snap-lock chimney to-
gether, it is important to assure the joint between 
chimney sections is locked. Check by pulling 
chimney upward after locking. The chimney 
will not come apart if properly locked. It is not 
necessary to add screws to keep the chimney 
together (exception, see Figure 9, page 9).
VenTing insTallaTion
Figure 5 - Outside Air Kit
Secure to Collars with Metal Tape, 
Screws or Straps (Min. 1/4" x 20" size)
Air Inlet 
Location 
Must Allow 
For Bushes 
or Snow
Vent Hood 
Required for 
Wall Installation
Air Inlet 
Eyebrow
Vented Crawl Space
(Check Local Codes 
Before Installing in a 
Vented Crawl Space)
CHIMNEY PIPE
The FMI PRODUCTS, LLC chimney system 
consists of 12", 18", 24", 36" and 48" snap-
lock,  double-wall  pipe  segments,  planned 
for  maximum  adaptability  to  individual  site 
requirements. Actual  lengths  gained  after 
fitting overlaps must be taken into consider-
ation (lineal gain) and are given in the lineal 
gain chart (see Figure 6). Lineal Gain is the 
actual measurable length of a part after two 
or more parts are connected. For Canada, 
use chimney parts designated "HT".
 WARNING: The opening in 
the collar around the chimney at 
the top of the fireplace must not 
be obstructed. Never use blown 
insulation  to  fill  the  chimney 
enclosure.
OPTIONAL OUTSIDE AIR KIT 
(MODEL AK4/AK4F)
The  installation  of  an  outside  air  kit  should 
be  performed  during  the  rough  framing  of 
the fireplace due to the nature of it's location. 
Outside combustion air is accessed through 
a  vented  crawl  space  (AK4F)  or  through  a 
sidewall (AK4).
  CAUTION:  Combustion  air 
inlet  ducts  shall  not  terminate 
in attic space.