VenTing insTallaTion
Continued
Figure 9 - Elbow Offset
B
A
Screws
FIRESTOP SPACERS (FS-10)
Firestop spacers are required at each point 
where the chimney penetrates a floor space. 
Their  purpose  is  to  establish  and  maintain 
the required clearance between the chimney 
and the combustible materials. When the pipe 
passes through a framed opening into a living 
space above, the firestop must be placed onto 
ceiling from below as shown in Figure 10.
They also provide complete separation from 
one floor space to another or attic space as 
required by most codes. When the double wall 
pipe passes through a framed opening into an 
attic space, the firestop must be placed into 
an attic floor as shown in Figure 11.
Figure 10 - Firestop Spacer with Living 
Space Above Ceiling
Figure 11 - Firestop Spacer with Attic 
Space Above Ceiling
Existing 
Ceiling 
Frame
Firestop 
Spacer
Screws or 
Staples 
(Min. of 8)
Firestop 
Spacer
Screws or Staples 
(Min. of 8)
PENETRATING ROOF
To maintain a 1" clearance to pipe on a roof with 
a pitch, a rectangular opening must be cut.
1.  Determine the center point through which 
pipe will penetrate roof.
2.  Determine the center point of the roof. Pitch 
is the distance the roof drops over a given 
span, usually 12". A 6/12 pitch means that 
the roof drops 6" for each 12" one measure 
horizontally down from the roof rafters.
3.  Use the roof opening chart (Figure 12) to 
determine the correct opening length and 
flashing required.
4.  Remove  shingles  around  the  opening 
measured. Cut out this section.
5.  Add  next  sections  of  pipe  until  the  end 
penetrates roof line. Check to see that the 
proper clearances are maintained. Extend 
chimney  by  adding  sections  of  double 
wall  pipe  until  pipe  is  minimum  of  30" 
above the highest point of the roof cutout. 
Termination and chimney must extend a 
minimum of 36" above the highest point 
where it passes through the roof.
19.5" Min.
30" Min.
2" Min.
2" Min.
2" Min.
Opening "A"
Pitch
Slope Opening 
"A" Max. 
Used Flashing
Model No. 
Flat
19.5"
V6F-10DM
0-6/12
26.6°
22"
V6F-10DM
6/12- 12/12 45.0°
27"
V12F-10DM
Existing 
Ceiling 
Frame
Figure 12 - Roof Opening Measurements
FLASHING INSTALLATION (v6F-10DM 
OR v12F-10DM)
Determine flashing to be used with the roof 
opening chart. Slide flashing over pipe until 
base  is  flat  against  roof.  Replace  as  many 
shingles  as  needed  to  cover  exposed  area 
and flashing base. Secure in position by nailing 
through shingles (see Figure 13, page 10). DO 
NOT NAIL THROUGH FLASHING CONE.