c) Pump-Out Timer (S4 dip switch 3 & 4)
When a pump-out is called for, the pump motor de-energizes after the preceding freeze 
cycle. The pump motor energizes  seconds later in the reverse direction, taking water 
from the bottom of the tank and forcing pressure against the check valve seat allowing 
water to go through the check valve and down the drain. At the same time, water flows 
through the small tube to power flush the float switch. The pump motor drains the water 
tank for the time determined by the pump-out timer. The pump-out timer also acts in 
place of the harvest timer during cycles with a pump-out. The pump-out timer is factory 
set, and generally no adjustment is required. However, where water quality is bad and 
the icemaker needs a longer pump-out time, the pump-out timer can be adjusted. The 
pump-out timer control can be set to pump-out for 0 or 0 seconds.
S4 Dip Switch Setting Time (seconds)
Inlet 
Water 
Valve
No. 3
No. 4
T1
T2
OFF
OFF
0
50
Closed
ON
OFF
0
80
Closed
OFF
ON
0
0
Open
ON
ON
0
80
Closed
T: Time to drain the water tank
T: Harvest timer at pump-out
d) Pump-Out Frequency Control (S4 dip switch 5 & 6)
The pump-out frequency control is factory set to drain the water tank every 0 cycles, 
and generally no adjustment is required. However, where water quality is bad and the 
icemaker needs a pump-out more often, the pump-out frequency can be adjusted. The 
pump-out frequency control can be set to have a pump-out occur every cycle, or every 
, 5, or 0 cycles. 
Timing of the first pump-out is dependent on the control board. "E" control board first 
pump-out is after the first freeze cycle. "G" control board first pump-out is dependent on 
S4 dip switch 5 & 6. See the table below.
"E" & "G" Control Board Settings
1st Pump-Out
S4 Dip Switch Setting
Pump-Out 
Frequency
"E" Control Board
"G" Control Board
No. 5
No. 6
OFF
OFF
Every cycle
After st freeze cycle
After nd freeze cycle
ON
OFF
Every  cycles
After 3rd freeze cycle
OFF
ON
Every 5 cycles
After 6th freeze cycle
ON
ON
Every 0 cycles
After th freeze cycle