D. Bin Control
1. Thermostatic Bin Control: Auxiliary Code T-0, U-0
CAUTION
When the ambient temperature is below 45°F (7°C), the thermostatic bin 
control switch opens and shuts down the icemaker even if the ice storage bin 
is empty. When the thermostat is set in the prohibited range, the icemaker 
operates continuously even if the ice storage bin is filled with ice. Setting in the 
prohibited range may result in severe damage to the icemaker.
The thermostatic bin control switch is a temperature controlled switch used to control 
the level of ice in the bin. It is in line with the power supply to the control switch. 
The thermostatic bin control switch shuts down the unit within 0 seconds when ice 
contacts the thermostatic bulb, regardless of the cycle at activation. The thermostatic 
bin control is factory set, and generally no adjustment is required. However, 
adjustment may be needed in some conditions, particularly at higher altitude 
locations. For further details, see "IV.C.. Thermostatic Bin Control Check."
2. Mechanical Bin Control: Auxiliary Code U-1 and Later
The mechanical bin control is a lever-actuated bin control switch used to control the 
level of ice in the bin.
 
The mechanical bin control connects to the control board RED 
K4 connector. When the actuator paddle is not engaged (mechanical bin control 
switch closed; control board green "BC CLOSED" LED on), the unit produces ice. 
When the actuator paddle is engaged (mechanical bin control switch open; control 
board yellow "BC OPEN" LED on), the unit shuts down as outlined in the table below. 
Cycle at 
Mechanical Bin 
Control Activation
Shutdown 
Fill Cycle
5 seconds after activation.
Harvest Cycle
At the end of the harvest cycle, or up to 5 seconds into the freeze cycle if 
activated at the end of the harvest cycle.
Freeze Cycle
5 seconds after activation if activated at least 5 seconds before the 5-minute 
short cycle protection timer expires. Otherwise, at the end of the next harvest 
cycle. 
E. Float Switch
The float switch is used to determine that there is sufficient water in the tank after 
the -minute fill cycle and after each harvest cycle. The float switch is also used to 
determine that the appropriate volume of water has been converted into ice before 
switching out of the freeze cycle. No adjustment is required.
F. Thermistor
The thermistor is used as a harvest control sensor. The thermistor's resistance varies 
depending on the suction line temperature. The control board monitors the resistance to 
start the harvest timer. No adjustment is required.
G. Control Switch
The control switch has three positions: "OFF" for power off, "ICE" for icemaking, and 