Hoshizaki KM-901MAH 用户手册

下载
页码 87
58
2. Float Switch Cleaning
Depending on local water conditions, scale may build up on the float switch. Scale on 
the switch can cause the float to stick. In this case, the float switch should be cleaned. 
) Turn off the power supply.
) Remove the front panel, then move the control switch to the "OFF" position.
3) Remove the base cover, then disconnect one end of the pump tubing to drain the water 
tank. See Fig. . After the water tank has drained, reconnect the pump tubing.
4) Disconnect the vent tube and the flush tube from the top of the float switch, then 
remove the float switch assembly and remove the float switch assembly and remove 
the rubber boot from the bottom of the float switch assembly. See Fig. 3.
5) Remove the retainer rod from the bottom of the float switch housing, then remove the 
float. Be careful not to bend the retainer rod excessively when removing it.
6) Wipe down the float switch housing, shaft, float, and retainer rod with a mixture of 
 part of recommended cleaner Hoshizaki "Scale Away" or "LIME-A-WAY" (Economics 
Laboratory, Inc.) and 5 parts of warm water. Clean the inside of the rubber boot and 
hose with cleaning solution. Rinse the parts thoroughly with clean water.
7) Reassemble the float switch assembly and replace it and the rubber boot in their 
correct positions. Reconnect the vent tube and the flush tube.
8) Move the control switch to the "ICE" position.
9) Replace the front panel in its correct position.
Fig. 3
Float
Float Switch 
Housing
Rubber Boot 
and Hose
Retainer Rod
Flush 
Vent 
Shaft