Alcatel-Lucent 6850-48 参考指南

下载
页码 3444
Ethernet OAM Commands
OmniSwitch CLI Reference Guide
September 2009
page 28-11
ethoam association ccm-interval
Modifies the Continuity Check Message (CCM) transmission interval of an Ethernet OAM Maintenance 
Association.
ethoam association association_name domain {domain_name | mac_address
ccm-interval
 {interval-invalid |
  
interval1s | interval10s | interval1m interval10m}
Syntax Definitions
association_name
Name of the Ethernet OAM Association. Up to 48 (minus the domain 
name length) characters may be used.
domain_name
Specifies the domain name. For more information on the different 
formats of the domain name, refer to 
mac_address
Specifies the CFM system MAC address.
interval-invalid
Specifies that no CCMs are sent by a MEP
interval1s
Specifies that CCMs are sent every 1 second.
interval10s
Specifies that CCMs are sent every 10 seconds.
interval1m
Specifies that CCMs are sent every minute.
interval10m
Specifies that CCMs are sent every 10 minutes.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
The association_name should be unique amid all those used by or available to the service provider within 
a domain.
Examples
-> ethoam association alcatel-sales domain esd.alcatel-lucent.com ccm-interval 
interval10s
parameter
default
interval-invalid | interval1s | 
interval10s | interval1m | 
interval10m
interval10s