Section 2  Engineering Guidelines
61200305L2-1B
© 2004 ADTRAN, Inc.
33
External Alarm Relay Monitor Connection
This connection alerts the user when a selected external alarm condition exists. This connection could be 
used to monitor a UPS with dry contacts or another ATLAS 550. The 2-pin, removable terminal block 
connects with external wiring. Refer to DLP-14, Connecting the Alarm Contacts, for detailed instructions. 
Clear the alarm condition by pressing the 
ACO
 switch located on the front panel of the ATLAS 550. 
Table 6 shows the pinout for the External Alarm Relay connector. 
Alarm Relay Connection
This connection alerts the user when a selected alarm condition exists. The 4-pin, removable terminal 
block connects with external wiring. Refer to DLP-14, Connecting the Alarm Contacts, for detailed 
instructions. Clear the alarm condition by pressing the ACO switch located on the front panel of the 
ATLAS 550. Table 7 shows the pinout for the Alarm Relay connector.
5.
NETWORK INTERFACE MODULES
The ATLAS 550 provides two Network Interface Slots that allow different types of interfaces to be used. 
Available Network Interface Modules include the following:
Table 6.  External Relay Monitor Connector Pinout
Pin
Name
Description
1
ALARM OUT Outputs EIA-232 level signal for connection to external alarm contacts.
2
ALARM IN
Monitors signal coming from external alarm contacts.
Table 7.  Alarm Relay Connector Pinout
Pin
Name
Description
1
NORMALLY CLOSED (NC)
Opens when a selected alarm condition is present.
2
NORMALLY OPEN (NO)
Closes when a selected alarm condition is present.
3
COMMON (COM)
Common connection between external circuitry and NC or NO 
terminal.
4
CHASSIS GROUND (GND)
Ground connection.