Roland SH-201 业主指南

下载
页码 84
 
68
 
Parameter list
 
These are settings that apply to the entire SH-201.
 
MIDI parameters
 
SYSTEM COMMON parameters
 
Parameter
Value
Explanation
Panel operation
 
MASTER LEVEL
0–127
Determines the overall volume of the SH-
201.
MASTER TUNE
415.30–
466.20 (Hz)
Tunes the entire SH-201. Specified in terms 
of the frequency of the A4 key.
Hold down the CANCEL button and turn the PITCH knob
MASTER KEY 
SHIFT
-24– +24
Shifts the pitch of the entire SH-201 upward 
or downward in semitone steps.
PATCH 
REMAIN
OFF, ON
If this is “ON,” the sound of the currently 
sounding patch will be maintained when 
you select a different patch.
 
1.
 
Hold down the CANCEL button and press the TAP button
 
2.
 
Press the PRESET button and then press the BANK D button
 
3.
 
Press the NUMBER 1 button
 
Lit:
 
 ON, 
 
Dark:
 
 OFF
 
4.
 
Press the CANCEL button
CLOCK 
SOURCE
PATCH, 
SYSTEM, 
MIDI, USB
Selects the synchronization source for the 
arpeggiator/recorder tempo.
 
PATCH:
 
 Synchronize to the tempo saved 
 
SYSTEM:
 
 Synchronize to the tempo that 
is common to the entire SH-201 system 
(SYSTEM TEMPO).
 
MIDI:
 
 Synchronize to MIDI messages re-
ceived via the MIDI IN connector.
 
USB:
 
 Synchronize to MIDI messages re-
ceived via the USB connector.
 
1.
 
Hold down the CANCEL button and press the TAP button
 
2.
 
Press the PRESET button and then press the BANK B button
 
3.
 
Press a NUMBER button (1–4)
 
1:
 
 PATCH, 
 
2:
 
 SYSTEM, 
 
3:
 
 MIDI, 
 
4:
 
 USB
 
4.
 
Press the CANCEL button
* Don’t set this to “MIDI” or “USB” unless you need to syn-
chronize the SH-201 to the MIDI clock from an external de-
vice. With these settings, the arpeggiator, recorder, tempo-
synchronized LFO, etc., will not work correctly.
SYSTEM 
TEMPO
5–300 
(BPM)
This is the common tempo value used by the 
entire SH-201 when the CLOCK SOURCE 
parameter (see above) is set to “SYSTEM.”
With the CLOCK SOURCE parameter set to “SYSTEM,” press 
the TEMPO buttons or press the TAP button three or more 
times at quarter-note intervals of the desired tempo (p. 22, p. 
26).
 
Parameter
Value
Explanation
Panel operation
 
RX/TX CHANNEL
1–16
Specifies the MIDI channel on which the SH-201 will 
transmit and receive MIDI messages.
 
1.
 
Hold down the CANCEL button and 
press the TAP button
 
2.
 
Press the PRESET button and then press 
the BANK A button
 
3.
 
Press a NUMBER button (1–8)
 
1–8 (Lit in red):
 
 1–8
 
1–8 (Lit in green):
 
 9–16
 
4.
 
Press the CANCEL button
MIDI-USB THRU
OFF, ON
If this is “ON,” MIDI messages received at the MIDI IN 
connector will be re-transmitted without change from 
the USB connector.
 
1.
 
Hold down the CANCEL button and 
press the TAP button
 
2.
 
Press the PRESET button and then press 
the BANK C button
 
3.
 
Press a NUMBER button (1, 2)
 
1:
 
 MIDI-USB THRU
 
2:
 
 SOFT THRU
 
Lit:
 
 ON, 
 
Dark:
 
 OFF
 
4.
 
Press the CANCEL button
SOFT THRU
OFF, ON
If this is “ON,” MIDI messages received at the MIDI IN 
connector will be re-transmitted without change from 
the MIDI OUT connector.
 
RECEIVE SWITCH
 
PROGRAM 
CHANGE
OFF, ON
If this is “ON,” the patch number or the patch bank (A–
D) will change when a program change message is re-
ceived.
 
1.
 
Hold down the CANCEL button and 
press the TAP button
 
2.
 
Press the PRESET button and then press 
the BANK C button
 
3.
 
Press a NUMBER button (3, 4)
 
3:
 
 PROGRAM CHANGE
 
4:
 
 BANK SELECT
 
Lit:
 
 ON, 
 
Dark:
 
 OFF
 
4.
 
Press the CANCEL button
BANK SELECT
OFF, ON
If this is “ON,” the patch group (PRESET/USER) will 
change when a MIDI bank select message is received.
SH-201_r_e.book 68 ページ 2006年4月27日 木曜日 午前11時28分