Roland v-synth xt 业主指南

下载
页码 212
 
133
Disk-Related Functions (Disk Mode)
 
Disk-Related Functions (Disk Mode)
 
3.
 
To save to internal memory, touch <Int>. To save to memory 
card, touch <Card>. Then select the save-destination 
project.
 
If you want to save the data as a new project, touch <New 
Project>. The PROJECT Name window will appear. Assign a 
name to the new project.
 
4.
 
Touch <OK>.
 
A WARNING window like the following appears.
 
fig.06-07_50
 
If you want to cancel the procedure at this point, touch 
<CANCEL>.
 
5.
 
Touch <EXECUTE> to execute the operation.
 
Delete Unneeded Files 
 
(Clean Project)
 
This lets you clean up the contents of the disk by deleting files that 
cannot be used by the V-Synth XT or waves that are not used by 
patches. Executing this operation can increase the free space 
available on the disk. This operation can also be used to renumber 
the patches/waves so that any numbers that weren’t being used are 
put to use, thus bringing up the slack.
 
renumbered.
 
If the current project is in Internal memory, all internal memory 
will be cleaned up. If the current project is on a memory card, 
only the current project will be cleaned up.
 
1.
 
Access the DISK UTILITY MENU screen.
 
2.
 
Touch <Clean Project>.
 
The DISK Clean Project screen appears.
 
fig.10_50
 
3.
 
Touch the check boxes to choose what the Clean Project 
command is to do.
Keep unused user waves.:
 
Check this box if you want to keep all the waves you’ve sampled 
or imported from an external device (user waves).
 
Keep patch numbering.:
 
Check this box if you don’t want patches to be renumbered to fill 
up any unused patch numbers.
 
4.
 
Touch <EXECUTE> to execute the operation.
 
Importing Individual Patch or 
 
Wave Files (Import Files)
 
You can import individual patch or wave files or folders into the 
work area of the V-Synth XT.
 
Be aware that if patches created on a V-Synth with a system 
version older than 2.0 (i.e., versions 1.00 through 1.51 of the 
system) use preset PCM waves, those patches will not play 
correctly on version 2.0.
 
The data will be imported into unused patch/wave numbers. 
Importing is not possible if there are no empty patches or waves.
 
1.
 
Upwardly compatible
Can be imported and played in version 2.0
Patches that use a PCM oscillator
Patches that use an analog oscillator
Patches that use an external input oscillator
Patches that use preset waves
Patches that use user waves
Not compatible
Will NOT play correctly in version 2.0
Upwardly compatible
Can be imported and played in version 2.0
V-SYNTH_XT_e2 133 ページ 2005年3月23日 水曜日 午後4時39分