10BASE-T LAN Requirements
CSX200 Family User’s Guide
23
Connecting UTP Cables to Ports 1 Through 12 
Before connecting a segment to the CSX200, check each end of the segment to verify wire 
crossover.
Connect a twisted pair segment to the CSX200 as follows:
1.
Ensure that the device at the other end of the segment is connected to the segment and is 
powered ON.
2.
. Connect the twisted pair segment to the CSX200 by inserting the RJ45 
connector on the twisted pair segment into the desired RJ45 port (ports 1 through 12).
Figure 2
 
CSX200 Twisted Pair Connection
3.
Verify that a Link exists by checking that the receive port (RCV) LED is on (flashing green or 
amber or on solid green). If the RCV LED is off, perform the following steps until it is on:
a.
Check that the 10BASE-T device at the other end of the twisted pair segment is ON and 
connected to the segment.
!
CAUTION
To establish a link, you must have an odd number of crossovers (preferably one) 
between 10BASE-T devices of the same type (i.e., from repeater to repeater or 
transceiver to transceiver).