Enterasys csx5500 快速安装指南

下载
页码 42
QUICK START
12      CyberSWITCH
Use <page down> and <page up> to view sections of the Release Notes. At anytime, you may 
press the <escape> key to continue with the installation.
4.
Follow the on-screen instructions to continue with the upgrade. After 2-3 minutes, you will be 
asked to select the platform type you are installing from a displayed list. Enter the Id of the 
platform type you are configuring. In most cases, the platform name is on the front of the 
machine being installed. If you cannot determine the platform being used, temporarily 
configure the platform type as “CSX Series,” then call Technical Support to help you identify 
the platform type. 
 If one of the following messages is displayed:
Couldn’t open the file C:\SYSTEM\PLATFORM.NEI
Error reading C:\SYSTEM\PLATFORM.NEI
Error reading platform type: there was no “n” in the string
Error reading platform type: type value is too large
Error reading platform type: type was not converted to an int
Error reading platform type: there is no “plat name” field
the diskettes you have are corrupted. Call your distributor or Technical Support for a new set.
5.
Follow the on-screen prompts for inserting diskettes # 2, # 3, and # 4.
6.
If you wish to upgrade the Manager at this time: 
a.
issue the 
quit 
command to terminate the system software
b.
insert the Manager diskette
c.
at the DOS prompt type
C:\ADMIN\UG_ADMIN <return>
d. follow the on-screen prompts to complete the Manager Upgrade
8.
Reboot to complete the Upgrade process.
Note:
Before you configure your CyberSWITCH, issue the 
ver 
command and check to make 
sure that you have selected the correct platform. If you have not selected the correct 
platform, you must reinstall your software and select the correct platform during the 
installation process.
R
EMOTE
 U
PGRADE
The remote upgrade feature will allow you to upgrade the CyberSWITCH by transferring the 
upgrade file and then remotely issuing a 
restart
 command. To accomplish this, you will need 
the 
rupgrade.bat
 and the latest 
autoexec.bat
 files, available with release 7.2 and beyond. 
To remotely upgrade the operational software, follow these steps:
1.
From the PC/workstation, Telnet to the CyberSWITCH and login as admin.
2.
Verify that the system is ready to receive TFTP upgrades:
Enter MANAGE MODE by typing 
manage
 
<RET> at the system prompt.
Using  the  MANAGE  MODE  command 
tftp
, verify that:
TFTP feature is enabled
TFTP server is enabled
TFTP server is assigned ADMIN file access rights 
Using  the  MANAGE  MODE  command 
fileattr
, verify that:
ADMIN has READ/WRITE access to CONFIG files