USER’S GUIDE
296      CyberSWITCH
C
ONFIGURING
 F
ORWARDING
 F
ILTERS
The configuration of Forwarding Filters is a two-part process. First you must name the filter, and 
then you must create a list of conditions for the filter. To add a condition, you must name a 
previously-created packet type, and then name the action to perform on the specified packet type 
(i.e., forward or discard). 
U
SING
 CFGEDIT
1.
Select Forwarding Filters from the IP Filter menu.
2.
Select Add a Forwarding Filter.
3.
Provide a unique name for the filter you are creating. The Conditions for Filter menu is then 
displayed, similar to the following. (Note that the newly-created Forwarding Filter has a final 
condition of DISCARD as a default.) 
4.
Select Add to add a condition.
5.
Enter the information for the condition: 
name the previously-defined packet type
specify the action to take when an IP packet matches that type (forward or discard)
A screen similar to the following will then be displayed:
6.
If the filter already has a forwarding condition (other than the final condition), an additional prompt 
is presented concerning the condition’s position within the filter. Enter the location within the 
filter where the condition is to be added:
at the beginning
at the end
after the existing condition with id number “n”.
Note:
If the Final Condition of the filter needs modification, do so via the “Change Default 
Condition” selection on the “Conditions for Filter” menu. In this screen context, default 
condition
 refers to final condition.
Conditions for Filter "Filt_One"
Final Condition
DISCARD
All Other Types
(1) Add,    (2) Change,    (3) Delete,    (4) Move a CONDITION, 
(5) Change Default Condition   or press <RET> for previous menu? 
Conditions for Filter "Filt_One"
id
1
FORWARD
"Type_Two"
Final Condition
DISCARD
All Other Types
(1) Add,    (2) Change,    (3) Delete,    (4) Move a CONDITION,
(5) Change Default Condition or <RET> to return to the previous menu?