Enterasys csx5500 用户指南

下载
页码 729
Central Site Remote Access Switch      297
C
ONFIGURING
 A
DVANCED
 IP R
OUTING
IP Filters
C
ONFIGURING
 C
ONNECTION
 F
ILTERS
The IP Connection Filter is used at the point when an IP packet attempts to establish an outbound 
connection in order to continue the forwarding process. Its configuration parallels that of 
forwarding filters.
U
SING
 CFGEDIT
1.
Select Connection Filter from the IP Filter menu.
2.
Enable the Connection Filter. (By default, the Connection Filter is disabled.)
3.
Select Edit the Connection Filter. A screen similar to the following will be displayed:
4.
Select Add to add a condition.
5.
Enter the name of the packet type to be forwarded. A screen similar to the following is then 
displayed:
6.
If the filter already has a forwarding condition (other than the final condition), an additional prompt 
is presented concerning the condition’s position within the filter. Enter the location within the 
filter where the condition is to be added:
at the beginning
at the end
after the existing condition with id number “n”.
Note:
If the Final Condition of the filter needs modification, do so via the Default Condition 
selection on the Conditions for Filter menu. In this screen context, default condition refers to 
final condition.
Conditions for "Connect_Filter"
Final Condition
DISCARD
All Other Types
(1) Add,    (2) Change,    (3) Delete,    (4) Move a CONDITION, 
(5) Change Default Condition   or press <RET> for previous menu? 
Conditions for "Connect_Filter"
id
1
FORWARD
"Type_Two"
Final Condition
DISCARD
All Other Types
(1) Add,    (2) Change,    (3) Delete,    (4) Move a CONDITION, 
(5) Change Default Condition   or press <RET> for previous menu?