Enterasys csx5500 用户指南

下载
页码 729
Central Site Remote Access Switch      447
V
ERIFYING
 R
OUTING
 P
ROTOCOLS
IPX
IPX R
OUTING
 O
PERATIONAL
?
To verify that IPX routing feature is properly operational, a local NetWare client, a local NetWare 
server and a remote NetWare server must be operational.
The following graphic illustrates an example network we will use to describe how to verify that IPX 
routing is operational. It uses IPX network addresses specific to the example. Substitute the IPX 
network numbers of your network when you perform the verification steps. The example also uses 
NetWare commands available for the Windows 95 workstation. Substitute the equivalent 
commands on your NetWare client.
IPX R
OUTING
 
OVER
 
A
 LAN C
ONNECTION
1.
Determine if SITE1 can access the local NetWare Server “local.” On SITE1’s administration 
console type:
ipx diag cc:1 <return>
Note:
Node address 1 is used by the NetWare servers as part of their internal address.
2.
If the system displays a response to the
 ipx diag
 command similar to:
received 3 components from cc:1
then IPX routing over that LAN port is operational.
3.
If this message is NOT displayed, then IPX routing over the LAN connection is not operational 
and the following message will most likely be displayed:
No response from <ipx-address>
a.
Verify that the routing entry for the destination network exists by entering the following 
console command:
ipx route
If the CyberSWITCH displays the route to the destination, it knows how to reach the local 
server’s internal network. Determine if this is a static route or a dynamic route learned via 
ISDN
CSX5500
CSX5500
Network AA
Network BB
NetWare
Client A
NetWare
Server
"local"
NetWare
Server
"remote"
Internal
Network CC
Internal
Network DD
"SITE1"
"SITE2"