Enterasys rbt-8100 安装指导

下载
页码 92
Physical Specifications
1-4 RBT-8100 Wireless Switch Overview
Physical Specifications
The physical specifications for the RBT‐8100 Wireless Switch are listed in 
Environmental Requirements
Ensure that the environmental requirements are within the ranges described in 
.
Table 1-4 Physical Specifications
Parameter 
Approximate Specification
Width
430 mm (16.93 in.)
Height
87.5 mm (3.445 in.)
Depth
672 mm (26.457 in.)
Table 1-5 Environmental Specifications 
Parameter
Description
Operating Temperature
10°C to 35°C (50°F to 95°F) with the maximum rate of change not to 
exceed 10°C per hour
Non-Operating Temperature
40°C to +70°C (104°F to 158°F)
Altitude
-60 meters (-197 feet) below sea level to 4000 meters (13,123 feet) 
above sea level
Non-Operating humidity
90%, non-condensing @ 35°C (95°F)
Acoustic noise
Sound Pressure: 55 dBA (Rackmount) in an idle state at typical office 
ambient temperature. (23 +/- degrees C)
Sound Power: 7.0 BA in an idle state at typical office ambient 
temperature. (23 +/- 2 degrees C)
Operating Shock
No errors with a half sine wave shock of 2G (with 11 millisecond 
duration).
Package Shock
Operational after a 24 -inch free fall, although cosmetic damage may 
be present (Chassis Weight 40-80 lbs)
ESD
+/-15kV per Intel Environmental test specification
System Cooling
Requirement in BTU/Hr
1826 BTU/hour