16
Drive, sled numbering
Logical Numbering
Logical numbering depends on the RAID 
configuration of the storage array. Current 
firmware includes RAID Level 0, RAID Level 5, 
RAID Level 1, RAID Level 10, Zoning and 
Partitioning capability and hot spare sleds. The 
default configuration is QuickRAID0 0 or JBOD 
(Just a Bunch of Disks), in a single zone. 
Examples
JBOD 
mode uses 24 LUNs. Each LUN is 
equivalent to one physical drive. The array can 
operate with several sleds missing, but the empty 
sled(s) are treated as offline and cannot be 
configured. 
RAID Level 0 (QuickRAID0 [n]) 
With a fully 
populated array, RAID 0 may be configured as 1, 
2, 3, 4, 6, or 12 LUNs. As RAID0 1, all 24 
physical drives are configured as a single stripe 
group or LUN. You may also configure two LUNs 
of 12 drives each, three LUNs of eight drives 
each, four LUNs of six drives each, six LUNs of 
four drives each and 12 LUNS of two drives each. 
(See Exhibit 5.2-3 in 
on page 52). The 
command assumes there are 24 drives available to 
configure the specified number of LUNS. 
RAID Level 1 (QuickRAID1)  
has no options: the 
array can be configured into six groups, LUNs 1-
6, with each LUN containing two physical sleds; 
each sled in the LUN would be a mirror image of 
the other sled in the LUN.
RAID Level 10 (QuickRAID10)  
The 
QuickRAID10 command first creates six 
mirrored groups, then stripes them into groups of 
one, two or three RAID 10 groups. Each group is 
a LUN. Issuing QuickRAID10 2, the 12 physical 
sleds are configured as six mirrored pairs, then 
striped into two LUNs.
RAID Level 5 (QuickRAID5)  
with a fully 
populated Array may be configured as 1, 2, 3 or 4 
LUNs. As QuickRAID5 1, all 24 physical drives 
are configured as a single RAID 5 LUN. You may 
also configure two LUNs of 12 drives each, three 
LUNs of eight drives each, or four LUNs of six 
drives each. RAID Level 5 parity reduces the 
usable capacity of each LUN by the equivalent of 
one drive sled.
Unique serial number for each LUN
Each LUN in a system has a unique 24-character 
serial number which is updated when a system 
configuration changes. It is stored in a Device 
Association Table on each drive. 
When a drive or sled is replaced in QuickRAID 
configurations that allow for hot swap, a new 
serial number is computed and is stamped onto all 
member drives of the RAID group. The CLI 
command 
LUNInfo 
or the Logical Units
 
page of 
the ExpressNAV interface displays the serial 
number for each drive.
Exhibit 3.3-1   Format of the 24 characters of the unique serial number for each LUN
Character Placement Valid values
Example of unique serial number for a JBOD configuration:
 
1231231231231231231XAC0
 0-19
Any ASCII char Drive Serial Number
20
1 for RAID1 
A for RAID10
0 for RAID0
5 for RAID5
X for JBOD
RAID Configuration Character
21
A – Z
LUN Configuration Iteration Character: starts at A and increments every time 
a member drive is replaced in a RAID Group. Reverts back to A any time the 
Generation Character is updated
22
A – Z
Generation Character: starts at A and increments every time a new 
configuration is stamped on the system.  When it reaches Z, rolls over to A.
23
0
Reserved for future use