Connecting to a PC and powering the VDR
Vpacket 5100/6100 Series Installer’s Guide
                                                                                                 
Connecting to a PC and powering the VDR 
To configure the 5100/6100 VDR for the first time, you must connect an ASCII-based terminal, 
a PC running terminal-emulation software (such as HyperTerminal), or a modem. After 
initialization, you can set up the 5100/6100 VDR for remote management through telnet sessions 
or via the Internet through a web browser. See the data reference portion of the documentation 
CD-ROM for details.
The following procedure describes how to connect a terminal or PC to the 5100/6100 VDR 
console port using a 9-pin to 9-pin serial cable, which has a 26 AWG rating. If the terminal or PC 
has a 25-pin port, you also need a 9-pin-to-25-pin adapter.
The 5100/6100 VDR automatically power cycles when sufficient power is detected.
To connect the 5100/6100 to a PC or terminal
1. Connect one end of the serial cable to the Console connector on the back panel of the 5100/
6100 VDR. 
2. Connect the other end of the cable to your PC or terminal. 
3. Connect the supplied power supply cord to the power receptacle on the back panel of the 
5100/6100 VDR.
4. Connect the 3-pronged end of the power supply cord to an AC power outlet.
The unit automatically begins to power cycle once sufficient power is provided.
Note. When making this connection, the power cord can rest on top of the RJ21 
cable; however, it must not be situated below the RJ21 cable.
When connecting to the wall outlet, choose an outlet that is not controlled by a wall 
switch, which can accidentally turn off AC power to the 5100/6100 VDR. 
The LEDs cycle as the unit performs its Power-On Self-Test (POST), which lasts 
approximately 30 seconds. 
5. Following the test, confirm that the 5100/6100 VDR is receiving power by verifying that the 
Power LED on the front panel is on. If this LED is off, contact Vpacket Technical Support at 
(408) 571-7900. For warranty and Extended Warranty support, call 1(866) 872-2538.
6. Configure the terminal or the terminal-emulation software running on the PC to use the 
following parameters:
Baud rate: 57600 bps
Stop bits: 1
Data bit: 8
Parity: None
Hardware flow control: None