Zhone 6300 用户手册

下载
页码 146
C. Traps and MIBs
C-4
  
November 
2003
6300-A2-GB20-10
System Group
System Group objects are fully supported by the DSL router, as shown in 
NOTE:
The System Name, System Contact, and System Location objects can be 
configured via the port card (A-F). Values will display in Monitoring (B-E). 
However, the DSL router uses and displays the SNMP information set via the 
System Group.
Table C-2.
System Group Objects (1 of 2) 
Object
Description
Setting/Contents
sysDescr
(system 1)
Provides a full name and 
version identification for the 
Hotwire system’s hardware 
and software.
 
The object is set to display a string in the following format: 
PARADYNE Hotwire DSL; Model: xxxx-xx-xxx
S/W Release: yyy.yy.yy; H/W Release: zzzz-zzz; 
Serial Number: ssssssssssss; Boot: Bbb.bb.bb; 
2nd Boot: Sxx.xx.xx; DSP: x.xx
Model starts with the 4-digit model number:
„
6301 – IDSL router
„
6302 – IDSL 4-port router
„
6341 – SDSL router
„
6342 – SDSL 4-port router
„
6351 – ReachDSL router
„
6371 – RADSL router
sysObjectID
(system 2)
Identifies the network 
management subsystem for 
the DSL router.
OIDs (Object Identifiers):
„
6301 IDSL router – 1.3.6.1.4.1.1795.1.14.9.9.35
„
6302 IDSL 4-port router – 1.3.6.1.4.1.1795.1.14.9.9.36
„
6341 SDSL router – 1.3.6.1.4.1.1795.1.14.9.9.25
„
6342 SDSL 4-port router – 1.3.6.1.4.1.1795.1.14.9.9.26
„
6351 ReachDSL router – 1.3.6.1.4.1.1795.1.14.9.9.39
„
6371 RADSL router – 1.3.6.1.4.1.1795.1.14.9.9.29
sysContact
(system 4)
Provides the contact 
information for the person 
managing the DSL router.
ASCII character string (32 characters), as set by the user:
„
badValue(3) – Field length exceeded.
sysName
(system 5)
Provides a contact name for 
the DSL router.
ASCII character string (32 characters), as set by the user: 
„
badValue(3) – Field length exceeded.
sysLocation
(system 6)
Provides the physical location 
for the DSL router.
ASCII character string (32 characters), as set by the user:
„
badValue(3) – Field length exceeded.