  Chapter 1  Hardware overview
NN46110-313 02.01
Connecting the power cord
You must order the power cord for the VPN Router 1010/1050/1100 separately. 
The power cord must meet the requirements described in 
To connect the power cord and turn on the power:
1
Plug the power cord into the AC receptacle on the external power supply 
shipped with the VPN Router 1010/1050/1100.
Caution: 
Risk of equipment damage
 
Do not modify or use the AC power cord if it is not the exact type that is 
required for your power outlet.
Table 2   
Power cord requirements
Requirement
Description
Current rating
The power cord must be rated for the available AC voltage 
and must have a current rating that is at least 125 percent of 
the gateway’s current rating (1.5 A).
Certification
The power cord must have certification marks from an 
acceptable regional agency.
Cord length and flexibility The power cord must be less than 4.5 meters (14.7 feet) long. 
It must be a flexible HAR (harmonized) cord or VDE-certified 
cordage to comply with the gateway’s safety certifications.
Power supply connector
The connector that you plug into the AC receptacle on the 
gateway power supply must be an IEC 320, Sheet C5 female.
Wall outlet connector
The power cord must terminate in a male plug with 
appropriate grounding.
Caution: Before you connect the power supply to the gateway, connect 
the cables to the Ethernet and serial ports. If you have a VPN Router 
1100, also connect the cables to the ports on any installed option cards.