show t1 ds1 summary
308689-B Rev 00
159
 
Setup Alarm Threshold
Minimum amount of time required before entering (or 
exiting) an alarm state due to changes on the DS1.
Clear Alarm Threshold
Fdl Address
One of two Facility Data Link (FDL) target address 
modes. It determines whether the near-end FDL will 
respond to High Level Data Link Control (HDLC) address 
AZ or BY in the FDL messages received from the far end.
Fdl Type
Attribute used to configure the FDL type. The ANSI403 
configures the port to use the FDL exchange described in 
the ANSI T1 403 specification. ATT54016 is used to 
configure the port for the FDL exchange listed in the 
AT&T 54016 document. NONE is used when no FDL is 
desired. The FDL can only be used when the line type is 
ESF.
Fdl Prm Cr Send/Accept
Performance message as originating from either a carrier 
or customer installation (CI).  As the performance 
message is sent out the FDL, the PRM Opening Address 
Cr bit is either set (Carrier) or cleared (CI). 
Fdl Loop Retention
Loop retention interframe time fill for the FDL after 
sending loopup code. Also, displays whether the DS1 
requires a loop retention code to be sent after a loopup 
request.
Accept Loopbacks
Whether the DS1 will accept or reject loop code requests 
(MCT3 link module is capable of detecting loopup and 
loopdown codes received from the far end.)
Loopback State
Current loopback state of this interface. The interface can 
be in one the following states: payload loopback, line 
loopback, or no loopback.
Loopback Action
Whether the DS1 was sent into either line loopback or 
payload loopback by the local network management. 
Code Sent
Type of code last sent across the MCT3 circuit by the 
device. Possible values are: sendnocode, sendlinecode, 
sendpayloadcode, sendqrs, and sendothertestpattern.