Nortel 15000 用户指南

下载
页码 148
Managing Events
302768-C Rev 00
4-5
 
Applying Read Filters to the Event Log
To display the events stored in all event buffers, enter the following command:
log
The system sorts the events and displays them in chronological order.
To limit the display of events, enter the 
log
 command as follows:
log 
[
<vol>
:
<log_file>
] [
-d
<date>
] [
-t
<time>
] [
-e
<entity>
] [
-f
<severity>
] 
[
-s
<slot_ID>
] [
-p
<rate>
] [
-c
<code_no.>
] [
-w
]
You can enter any combination of the following optional arguments:
vol:log_file
 specifies the volume number where a log file is located and the name 
of the log file. The system displays the events saved to this file.
date
 is the date in mm/dd/yy format. The system displays the events logged on and 
after that date.
time
 is the time in hh:mm:ss format. You can enter ranges from 00:00:00 to 
23:59:59. The system displays the events logged at and after that time.
entity
 is a software service that logs events. When the entity contains spaces, 
enclose it in quotation marks. Use uppercase letters when specifying the entity 
name. For a list of the entities, see the event database.
severity
 is one or more letter codes for an event type. The system displays the 
events by type. The severity codes are 
f
 or 
F
 for fault, 
i
 or 
I
 for informational, 
t
 or 
T
 for trace, 
w
 or 
W
 for warning, and 
d
 or 
D
 for debug. (Debug events are intended 
only for Nortel Networks Technical Solutions Center personnel.)
slot_ID
 is the number of the slot containing an SSP. The system displays the events 
associated with the processor. 
Note: 
To stop the command, press [Control-c] (hold down the Control key and 
press c).