Printed on: 07/13/05 
communication and will only transmit following the completion of any communication exchanges in 
progress or pending.  
7.1.3.1  Notification Packet Description 
Application Header: 
  
Command DC_FPD 
0x03 
Data Count 
42 
0x2A 
Application Data: 
 
  
Data[0] - Data[20] 
Line1 
ch ch ch… 0x00 
Data[21] - Data[41] 
Line2 
ch ch ch … 0x00 
 
7.1.3.2 Data Description 
Line1 
Data Type: 
Null (0x00) terminated ASCII character string. 
Max Length: 
DISP_LINE_LENGTH defined in 
Line2 
Data Type: 
Null (0x00) terminated ASCII character string. 
Max Length: 
DISP_LINE_LENGTH defined in 
 
 
The MC-12 includes 8 custom characters that are defined to display increments of a display block.  (i.e. 
Volume Bar)  The custom characters are ASCII character codes 8E - 93(hex).  The codes are used as 
follows: 
 '8E' - empty cell 
 
 
 '8F' - left 1 bar 
 
 
 '90' - left 2 bars 
 
 
 '91' - left 3 bars 
 
 
 '92' - left 4 bars 
 
 
 '93' - full cell 
7.1.3.3 HOST Response 
The MC-12 does not expect  any response from the HOST. 
7.1.4  MC-1 Parameter Change (MC-12,  MC-1) 
MC-12 will transmit predetermined parameter change notifications. If a parameter value is changed due to 
any user action or system action the MC-12 will transmit the current value of the parameter that is 
changing. 
 
This command has been maintained for backward compatibility with MC-1.  In order to maintain backward 
compatibility, the MC-12 Parameters have been mapped to the MC-1 parameters as described in the 
Supported System Parameters table listed below.   
 
The MC-12 with s/w V3.0 will disable this notification by default. 
 
This notifications can be enabled and disabled by using the commands described in 7.3.31 Get 
Communication Configuration (MC-12, MC-1)
  and  7.3.32 Set Communication Configuration (MC-12, 
MC-1). 
 
© 2005 Harman Specialty Group All rights reserved. 
 