MC-12 Serial Communications Protocol 
 
Printed on: 07/13/05 
 
 
Data Type: 
Null (0x00) terminated ASCII string. 
 
 
Max Length: 
21 (20 characters plus terminating Null) 
 
 
7.3.44  MC-12 Clear All Parameter Notifications (MC-12) 
Request to the MC-12 to disable all MC-12 parameter notifications. 
 
7.3.44.1  Command Packet Description 
Application Header: 
  
Command MC_CMD_CLEAR_ALL_PARAM_NOTIFICATIONS 0x3D 
Data Count 
0x00 
Application Data: 
  
  
N/A 
  
 
 
7.3.45  MC-12 Get System Status (MC-12) 
Request to MC-12 for its current system status.  MC-12 will respond with “System Status Packet”. 
 
7.3.45.1  Command Packet Description 
Application Header: 
  
Command MC_CMD_GET_SYS_STATUS  0x3E 
Data Count  0 
0x00 
Application Data: 
  
  
N/A 
  
 
7.3.45.2   System Status Response Packet 
Application Header: 
  
Command MC_RESP_SYS_STATUS 0x94 
Data Count  10 
0x0A 
Application Data: 
  
Data[0] System 
Volume 
nn 
Data[1] Current 
Input 
nn 
Data[2] 
Current Effect Id  
nn 
Data[3] 
Current Input Sample Rate  nn 
Data[4] 
Current Input Format 
nn 
Data[5] Mute 
Active 
nn 
Data[6] Effect 
Bypass 
nn 
Data[7] Left/Right 
Balance 
nn 
Data[8] Front/Back 
Balance 
nn 
Data[9] Video 
Sync 
nn 
 
7.3.45.3 Data Description 
 System 
Volume: 
© 2005 Harman Specialty Group All rights reserved. 
 