Lexicon 
MC-12 Serial Communications Protocol 
 
Printed on: 07/13/05 
Min: 
 
 
-16 (0xF0) (Full Back) 
 
Video Sync: 
Data Type: 
 
Boolean. 
TRUE:   
 
MC-12 has detected Video Sync for current video input 
FALSE:  
 
MC-12 can not detect Video Sync for the current video input 
 
 
 
7.3.46  MC-12 Get Record Status (MC-12) 
This command is a request to MC-12 for current Zone 2 Status. MC-12 will respond with “Zone2 Status 
Packet”. 
 
7.3.46.1  Command Packet Description 
Application Header: 
  
Command MC_CMD_GET_REC_STATUS  0x3F 
Data Count  0 
0x00 
Application Data: 
  
  
N/A 
  
 
7.3.46.2  Zone2 Status Response Packet 
Application Header: 
  
Command MC_RESP_REC_STATUS 
0x95 
Data Count 5 
0x05 
  
Application Data: 
Data[0] Zone2 
Volume 
nn 
Data[1] 
Assigned Zone 2 Input 
nn 
Data[2] 
Zone2 Mute Active 
nn 
Data[3] Record 
Active 
nn 
Data[4] Zone2 
Balance 
nn 
 
7.3.46.3 Data Description 
 
 
Zone2 Volume: 
Data Type: 
 
Signed 8 bit integer (2’s compliment) 
Max: 
 
 
+12 (0x0C) (12 dB) 
Min: 
 
 
-80 dB (0xB0) (-80 dB) 
 
 
 
 
 
Assigned Zone 2 Input: 
 
 
Indicates the Zone 2 input that is currently assigned for the zone 2 outputs. 
Data Type: 
 
Unsigned 8 bit integer. 
Definition/Conversion: 
 
 
Zone2 Mute Active: 
Data Type: 
 
Boolean. 
TRUE:   
 
Zone2 Outputs are active. 
FALSE:  
 
 
Zone 2 Outputs are not active. 
© 2005 Harman Specialty Group All rights reserved. 
 