z
Execute the shutdown or undo shutdown command to an idle interface on the agent, and the
NMS receives the corresponding trap.
SNMP Logging Configuration Example
Network requirements
z
As shown in
, the NMS and the agent are connected through an Ethernet.
z
The IP address of the NMS is 1.1.1.2/24
z
The IP address of the agent is 1.1.1.1/24
z
Configure SNMP logging on the agent to record the operations performed by the NMS to the agent
Figure 1-5 Network diagram for SNMP logging
Configuration procedure
For the configurations for the NMS and agent, refer to
and
# Enable logging display on the terminal. (This function is enabled by default, so that you can omit this
configuration).
<Sysname> terminal monitor
<Sysname> terminal logging
# Enable the information center to output the system information with the severity level equal to or
higher than informational to the console port.
<Sysname> system-view
[Sysname] info-center source snmp channel console log level informational
# Enable SNMP logging on the agent to log the GET and SET operations of the NMS.
[Sysname] snmp-agent log get-operation
[Sysname] snmp-agent log set-operation
z
The following log information is displayed on the terminal when the NMS performs the Get
operation to the agent.
%Jan 1 02:49:40:566 2006 Sysname SNMP/6/GET: