ICOM IC-7000 说明手册

下载
页码 166
28
3
BASIC OPERATION
3
The triple band stacking register provides 3 memories
in one band. 3 sets of frequency and operating mode
on each band are automatically stored when used.
If a band key (on the HM-151) is pushed once, the last
used frequency and operating mode on that band are
called up. When the key is pushed again, another
stored frequency and operating mode are called up.
This function is convenient when you operate 3 oper-
ating modes on one band. For example, one register
is used for a CW frequency, another for an SSB fre-
quency and the other one for an RTTY frequency.
See the table below for a list of the bands available
and the default settings for each band.
SPCH
  /LOCK
TUNER
  /CALL
XFC
V/M
F-1
F-2
FIL
MODE
GENE
MW
1
2
3
4
5
6
7
8
9
.
0
CE
F-INP
ENT
1.8
3.5
7
10
14
18
21
24
28
50
144
430
Band keys
HM-151
Selecting an operating band
BAND
REGISTER 1
REGISTER 2
REGISTER 3
1.8 MHz
1.900000 MHz CW
1.910000 MHz CW
1.915000 MHz CW
3.5 MHz
3.550000 MHz LSB
3.560000 MHz LSB
3.580000 MHz LSB
7 MHz
7.050000 MHz LSB
7.060000 MHz LSB
7.020000 MHz CW
10 MHz
10.120000 MHz CW
10.130000 MHz CW
10.140000 MHz CW
14 MHz
14.100000 MHz USB
14.200000 MHz USB
14.050000 MHz CW
18 MHz
18.100000 MHz USB
18.130000 MHz USB
18.150000 MHz USB
21 MHz
21.200000 MHz USB
21.300000 MHz USB
21.050000 MHz CW
24 MHz
24.950000 MHz USB
24.980000 MHz USB
24.900000 MHz CW
28 MHz
28.500000 MHz USB
29.500000 MHz USB
28.100000 MHz CW
50 MHz
50.100000 MHz USB
50.200000 MHz USB
51.000000 MHz FM
144 MHz
145.000000 MHz FM
145.100000 MHz FM
145.200000 MHz FM
430 MHz
433.000000 MHz FM
433.100000 MHz FM
433.200000 MHz FM
General
15.000000 MHz USB
15.100000 MHz USB
15.200000 MHz USB
q Push 
[(14)5]
, then select a frequency and an oper-
ating mode.
• Frequency and operating mode are memorized in the
first band stacking register.
w Push 
[(14)5]
again, then select another frequency
and operating mode.
• This frequency and operating mode are memorized in
the second band stacking register.
e Push 
[(14)5]
again, then select another frequency
and operating mode.
• This frequency and operating mode are memorized in
the third band stacking register.
• When a fourth frequency and operating mode are se-
lected on a band, the first register set in step q, is over
written.
SPCH
  /LOCK
TUNER
  /CALL
XFC
V/M
F-1
F-2
FIL
MODE
GENE
MW
1
2
3
4
5
6
7
8
9
.
0
CE
F-INP
ENT
1.8
3.5
7
10
14
18
21
24
28
50
144
430
FIL
MODE
GENE
1
2
3
4
5
6
7
8
9
.
0
CE
F-INP
ENT
1.8
3.5
7
10
14
18
21
24
28
50
144
430
[Example]: 14 MHz band
HM-151
D
D
Using the band stacking registers