Omnitron iConverter XG 8599-01-B 用户手册

产品代码
8599-01-B
下载
页码 4
Copper to Fiber Conversion Application
This  application  shows  two  10G  servers  with  copper  CX4 
interfaces in two different locations.  The servers need to be 
connected but are beyond the 15 meter distance limitation of 
a CX4 copper cable.  Using a pair of 8599-11 (XFP to XFP)  
iConverter XG media converters, the servers are connected 
via  multimode  fiber  (up  to  300m).    CX4  XFP  transceivers 
provide the connectivity between the media converters and 
the servers.
applications
CWDM Application
This application shows four 10G connections across a CWDM 
common fiber link (multi-color line)  where fiber availability is 
limited and CWDM multiplexers are used to increase the fiber 
capacity.
An iConverter 4-Channel CWDM/X multiplexer module and four 
iConverter XG 8599-01 (SFP+ to XFP) modules are installed 
in  a  5-Module  Chassis  at  both  locations.  The  iConverter 
XG  modules  are  used  as  transponders  to  convert  the  CX4 
interfaces  on  the  10G  switch  ports  to  CWDM  wavelengths 
required by the CWDM/X multiplexers.
Page 2
iConverter
 XG and XG+
Direct Connect/Fiber Conversion Application
This application shows two 10G switches with SFP+ ports  in 
two different locations.  The switches are connected via long-
haul, single-mode fiber (>80km) with a pair of iConverter XG 
8599-01 (SFP+to XFP) media converters.  In the top location, 
a low-cost SFP+ Direct Attach Cable is used to connect the 
10G switch port to the media converter because the distance 
is  within  the  10  meter  limit  of  the  Direct Attach  Cable.    In 
the bottom location, a pair of multimode SFP+ transceivers 
provide the connectivity between the media converters and 
the switches.
A CX4 transceiver is installed in port 1 on each iConverter 
XG.  A CX4 cable is used to connect the 10G switch ports to 
each converter.
The  second  port  of  each  iConverter  XG contains  an  SFP+ 
CWDM transceiver that generates a specific CWDM optical 
wavelength,  and  is  connected  to  the  CWDM/X  multiplexer 
with fiber patch cables (where each colored line represents a 
different wavelength).