Electrical Requirements - U.S.A. Only
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from: 
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.
Electrical Connection
Check local codes and consult gas supplier. Check existing 
electrical supply and gas supply. See “Gas Supply 
Requirements” sections.
It is recommended that all electrical connections be made by a 
licensed, qualified electrical installer.
Range must be connected to the proper electrical voltage 
and frequency as specified on the model/serial/rating plate. 
The model/serial/rating plate is located on the right vertical 
surface of the oven door frame. Refer to the illustrations in the 
“Product Dimensions” section of the “Location 
Requirements” section.
This range is manufactured with a 4-wire power supply cord 
rated at 240 volts, 40 amps, rated at 194°F (90°C) and 
investigated for use with this range.
*The NEC calculated load is less than the total connected load 
listed on the model/serial/rating plate.
When a 4-wire, single phase 240 volt, 60 Hz., AC only 
electrical supply is available, a 40-amp minimum circuit 
protection is required on 30" (76.2 cm) ranges, fused on both 
sides of the line.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a UL or CSA International 
Certified Power Cord intended to be plugged into a standard 
14-50R wall receptacle. Be sure the wall receptacle is within 
reach of range’s final location.
Do not use an extension cord.
The wiring diagram is located on the back of the range or in a 
clear plastic bag.
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or 
electrical shock.
Range Rating*
Specified Rating of Power 
Supply Cord Kit and 
Circuit Protection
120/240 Volts
120/208 Volts
Amps
Temp Rating
8.8 - 16.5 kW
16.6 - 22.5 kW
7.8 - 12.5 kW
12.6 - 18.5 kW
40 or 50
50
194°F (90°C)
194°F (90°C)