1  HOW TO MOUNT
1-4  Mounting the 
Accessories for Manual 
Control System
Mount and connect the flexible zoom and focus control units 
as shown in the figure.
When mounting the various demands, refer to the operation 
manual for the respective demand.
① Flexible module
② Flexible zoom control unit
③ Flexible focus control unit
④ Flexible cable
⑤ Switch box unit
Mounting the flexible module
It is necessary to mount the flexible module to the zoom and 
focus couplings located in the bottom compartment of the 
lens.
* (NOTE)
The same flexible module is used for both zoom and focus 
couplings. So, it can be mounted on either the zoom or focus 
coupling.
1
  Before mounting the module to the lens, turn the lock 
screw of the module counterclockwise until the lock 
axis comes out to its a half way of length.
2
  Press the module in the direction of arrow “A”, so 
that the key pins on the lens are inserted in the key 
grooves of the module.
3
  Mate the coupling A of the module with the coupling 
B of the lens. And then, fully push the module in the 
direction of arrow “B” until it stops.
4
  Finally, turn the lock screw of the module clockwise to 
secure it. By using a coin, tighten firmly the lock knob.
Next, as the same procedure, install the flexible module 
on the other joint. It does not matter which is installed first, 
either the zoom or the focus.
Bottom compartment of the lens
Key Pin
Arrow 
A
Lock Axis
Lock
Coupling B
Lock Screw
Key Groove
Coupling A
Arrow B