KitchenAid 36" Wall-Mount Canopy Hood 安装指南
9
4. Connect green (or bare) ground wire from home power supply
to the unused green ground screw (E) in the terminal box.
Tighten the ground screw.
Tighten the ground screw.
5. Push excess home supply cable back through the strain relief
and tighten strain relief screws. Use caulking to seal
openings.
openings.
6. Install terminal box cover.
7. Check all light bulbs to make sure they are secure in their
sockets.
8. Reconnect power.
Install Chimney Covers
For Vented Installations
1. Connect the vent system and seal all connections with
clamps.
Install Upper Chimney Cover
1. Slightly spread the sides of the cover apart and hook them
behind the chimney mounting brackets.
2. Attach the cover to the brackets with 4 mounting screws.
3. Securely tighten screws.
Install Lower Chimney Cover
1. Slightly spread the sides of the cover apart and hook them
behind the upper chimney and the wall. Slide the lower
chimney down to fit securely into the top of the range hood.
chimney down to fit securely into the top of the range hood.
NOTE: For vented installations, the lower chimney cover can
be installed with the vent slots at the top. For non-vented
(recirculating) installations, the lower chimney cover must be
installed with the vent slots at the bottom.
be installed with the vent slots at the top. For non-vented
(recirculating) installations, the lower chimney cover must be
installed with the vent slots at the bottom.
Complete Installation
1. Replace grease filters. See the “Range Hood Care” section.
2. Check the operation of the range hood fan and light. See
“Range Hood Use” section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
NOTE: To get the most efficient use from your new range hood,
read the “Range Hood Use” section.
read the “Range Hood Use” section.
A. 4 mounting screws
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
terminal box.
Failure to do so can result in death, fire, or
electrical shock.
electrical shock.
A
A
View shown with vent slot at the bottom
for non-vented (recirculating) installation
for non-vented (recirculating) installation