KitchenAid 30" Vented 400-CFM Wall-Mount Canopy Hood 使用和维护

下载
页码 32
10
Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install 
a UL listed or CSA approved
 ¹⁄₂" strain relief.
4. Run home power supply wiring through 
¹⁄₂" strain relief 
into terminal box.
5. Use UL listed wire connectors and connect white 
wires (B) together.
6. Use UL listed wire connectors and connect black 
wires (C) together.
7. Connect green (or bare) ground wire from home power supply 
to the 2 yellow-green ground wires (D) in terminal box using 
UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
Install Vent Covers
1. When using both upper and lower vent covers, push lower 
cover down onto hood and lift upper cover to ceiling and 
install with (2) 2.9 x 6.5 mm screws.
NOTE: For vented installations, the upper vent cover may 
be reversed to hide slots.
Complete Installation
1. For non-vented (recirculating) installations only, install 
charcoal filters over the grease filters, using the clips 
provided in the kit. See the “Range Hood Care” section.
2. Install metal filters. See the “Range Hood Care” section.
3. Check the operation of the range hood blower and light. 
See the “Range Hood Use” section.
NOTE: To get the most efficient use from your new range 
hood, read the “Range Hood Use” section.
A. UL listed wire connectors
B. White wires
C. Black wires
D. Green (or bare) wire connected to 
yellow-green wires
E. Home power supply
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.
A. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket
A
B
C
C
D