DOCUCOLOR 12 CUSTOMER SITE PLANNING GUIDE
11
External Digital Front End (Tier I DFE)
Electrical Service Outlet
and Space Requirements Worksheet
Electrical Service Outlet
and Space Requirements Worksheet
Since the DocuColor 12 requires a sole use outlet, the external
(Tier I) DFE cannot share the same outlet with the copier.
(Tier I) DFE cannot share the same outlet with the copier.
The power outlet for the DFE must be within a 3 foot radius from the
back of the unit for both stationary and movable installations, and
right and left side installations. See the following diagrams.
back of the unit for both stationary and movable installations, and
right and left side installations. See the following diagrams.
Minimum space requirements for Fiery DFEs:
•
24 inches (610 mm) on the right side or left side between the
DocuColor 12 or any accessories (High Capacity Feeder, Sorter/
Mailbox, or Edit Pad) and the DFE.
DocuColor 12 or any accessories (High Capacity Feeder, Sorter/
Mailbox, or Edit Pad) and the DFE.
•
24 inches (610 mm) between the DFE and the back wall.
•
2 inches (50 mm) between the DFE and a side wall.
Figure 1: Minimum space requirements for Fiery Servers
(not drawn to scale)
Back Wall
DocuColor 12
and optional
accessories (HCF,
Edit Pad, Sorter/
Mailbox)
Right side installation
Fiery
DFE
DFE
Left side installation
24 in.
(610 mm)
(610 mm)
24 in.
24 in.
(610 mm)
51 in.
(1295 mm)
51 in.
(1295 mm)
2 in.
(50 mm)
(50 mm)
2 in.
(50 mm)
Fiery
DFE
DFE