Honeywell TH1100DV 安装指南

下载
页码 24
PRO TH2000DV/TH1000DV Series
3
69-2800EFS—01
Power options
TH2110DV/TH1110DV:
Changeover valve energized in heating
Changeover valve energized in cooling
Fan relay
Compressor contactor
Heat relay
24 Vac common. For 2-transformer
systems, use common wire from
cooling transformer.
24 Vac power from heating transformer
Rc  24 Vac power from cooling transformer
TH2210DV/TH1210DV:
Changeover valve energized in
heating
Changeover valve energized in
cooling
Fan relay
Compressor contactor
Aux/E  Auxiliary heat relay
24 Vac common
24 Vac power
TH1100DV:
Heat relay
24 Vac common
24 Vac power
Terminal designations
Wiring
M32808B
R
W
Y
G
B
Rc
O
C
TH2110DV/
TH1110DV
C
Y
G
O
B
R
Aux/
E
M32809B
TH2210DV/TH1210DV
Not
Used
M34673
INSERT BATTERIES FOR
PRIMARY OR BACKUP POWER
M34699
KEEP WIRES IN
THIS SHADED AREA
REMOVE FACTORY-INSTALLED JUMPER
ONLY FOR TWO-TRANSFORMER SYSTEMS
CONNECT C FOR PRIMARY
AC POWER (OPTIONAL IF 
BATTERIES ARE INSTALLED)
RC
R
C
W
Y
G
O
B
TERMINAL
BLOCK SHOWN
M34800
R
W C
TH1100DH