Cisco Cisco Unified MeetingPlace Audio Server 维护手册

下载
页码 313
3-11
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8106)
78-16411-01
Chapter 3      Installing the 8106 Server
  Mounting the 8106 server
T1 CAS telephony cables for T1 Smart Blades (for systems using T1 CAS ports). Use these T1 CAS 
telephony cables to connect the T1 Smart Blades to the customer’s system
Note
The number of T1 CAS telephony cables you receive depends on the number of ports 
purchased for your system. You need one T1 CAS telephony cable for every 24 PSTN ports 
being activated.
E1 telephony cables (for systems using E1 ports). Use these E1 telephony cables connect to the front 
of the breakout box to the customer’s system
Note
The number of E1 telephony cables shipped with your system depends on how many Multi 
Access Blades are in the system. Sixteen cables are shipped for each Multi Access Blade.
T1 PRI telephony cables (for systems using T1 PRI ports). Use these T1 PRI telephony cables 
connect to the front of the breakout box to the customer’s system
Note
The number of T1 PRI telephony cables shipped with your system depends on how many 
Multi Access Blades are in the system. Sixteen cables are shipped for each Multi Access 
Blade.
applicable software, manuals, and license documents
In addition, the following items are shipped with systems requiring a breakout box (T1 PRI or E1 
configuration):
breakout box
screws for mounting the breakout box
trunk card interface cable assemblies (50-pin Amphenol cables)
Note
The number of trunk card interface cable assemblies shipped with your system depends on 
how many and the type of Multi Access Blades in the system. Two cables are shipped for 
each MA-16 and one cable is shipped for each MA-4.
Mounting the 8106 server
You must  mount and install the 8106 server in either of the following two types of racks:
19-inch frame relay rack
19-inch EIA equipment rack
This section describes how to mount and install the 8106 in a rack.
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special 
precautions to ensure that the system remains stable. The following guidelines are provided to ensure 
your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.