Cisco Cisco UCS C22 M3 Rack Server 数据表
Cisco UCS C22 M3 High-Density LFF Rack Server
TECHNICAL SPECIFICATIONS
67
The general power specifications for the C22 M3 LFF server 650 W power supply are listed in
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 35 UCS C22 M3 LFF 650 W Power Supply Specifications
Description
Specification
AC input voltage
90 to 264 VAC self-ranging,
100 to 120 VAC nominal
200 to 240 VAC nominal
100 to 120 VAC nominal
200 to 240 VAC nominal
AC input frequency
Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
Maximum AC input current
7.6 A maximum at 100 VAC
3.65 A maximum at 208 VAC
3.65 A maximum at 208 VAC
Maximum AC inrush current
11 A peak @ 35° C, 208 VAC
Maximum output power for the
power supply
650 W
Power supply output voltage
Main power: 12 VDC
Standby power: 12 VDC
Standby power: 12 VDC
Power supply efficiency
CSCI Platinum