Cisco Cisco 12000 Series 1-Port OC-48 STM-16 POS SDH ISE Line Card
30
Channelized and Electrical Interface Line Card Installation and Configuration
78-16417-02
Verifying and Troubleshooting the Line Card Installation
lists some approximate attenuation values from the ANSI standard, and shows the RG-179
attenuation. As you can see, RG-179 has a much higher attenuation, so take this information into account
if you plan long runs of RG-179 cable.
if you plan long runs of RG-179 cable.
Verifying and Troubleshooting the Line Card Installation
The following sections describe how to verify and troubleshoot the line card installation:
•
•
•
•
•
Initial Boot Process
Note
Many new line cards are designated as administratively down by default. Status LEDs are off until you
configure the interfaces and use the no shutdown command.
configure the interfaces and use the no shutdown command.
During a typical line card boot process, the following events occur:
1.
The line card maintenance bus (MBus) module receives power and begins executing the MBus
software.
software.
2.
The line card MBus module determines the type of card on which it resides, performs internal
checks, and prepares to accept the Cisco IOS software from the RP.
checks, and prepares to accept the Cisco IOS software from the RP.
3.
The RP powers up the line card and loads the line card with its Cisco IOS software.
To verify that the line card is working properly, perform the following operational checks:
•
During the line card boot process, observe the line card alphanumeric LEDs to ensure that the card
is running the typical initialization sequence. The sequence should end with IOS RUN.
is running the typical initialization sequence. The sequence should end with IOS RUN.
•
Observe the line card status LEDs to verify that the Active LED (Link LED or status LED for line
cards with no Active LED) is on. If an Active LED is not on, verify that the associated interface is
not shut down.
cards with no Active LED) is on. If an Active LED is not on, verify that the associated interface is
not shut down.
Table 12
ANSI Standard Cable-Attenuation Values
Approximate Cable Attenuation (dB) from ANSI Standard T1.404-1994
DSX-3 Point
Transmitter-to-receiver
distance (max)
distance (max)
RG-179
Frequency
100 ft (30 meters)
450 ft (137 meters)
900 ft (274 meters)
100 ft (30 meters)
1 MHz
0.27
1.2
2.4
3.0
10 MHz
0.80
3.6
7.2
5.3
50 MHz
1.82
8.2
16.4
8.5
100 MHz
2.64
11.9
23.8
10.0