Cisco Cisco Firepower Management Center 2000 發佈版本通知

下载
页码 36
16
FireSIGHT System Release Notes
Installing the Update
optionally, updating your intrusion rules and vulnerability database (VDB) and reapplying your access control policies
making any required configuration changes based on the information in 
The next sections include detailed instructions not only on performing the update, but also on completing any 
post-update steps. Make sure you complete all of the listed tasks.
Updating Defense Centers
Use the procedure in this section to update your Defense Centers, including virtual Defense Centers. For the Version 
5.4.1.2 update, Defense Centers reboot.
Caution:
 If your MC2000 or MC4000 is not running BIOS Version 2.0.1b before you update to Version 5.4.1.2, the update 
will fail. Press F2 during appliance boot to open the BIOS setup utility and confirm the BIOS version. If you need to update 
the BIOS or if the update fails due to the BIOS version, contact Support.
Caution:
 Before you update the Defense Center, reapply access control policies to any managed devices. Otherwise, 
the eventual update of the managed device may fail.
Caution:
 Do not reboot or shut down your appliances during the update until after you see the login prompt. The system 
may appear inactive during the pre-checks portion of the update; this is expected behavior and does not require you to 
reboot or shut down your appliances.
Note: 
Updating a Defense Center to Version 5.4.1.2 removes existing uninstallers from the appliance.
Note: 
If you have inline normalization enabled and you update a Defense Center currently running Version 5.3.x to Version 
5.4, the update process does not change the behavior of your policies. The system adds user layers as necessary to 
preserve the settings that carried over.
Note:
 If you plan on updating the system to Version 6.0, you must install the FireSIGHT System Version 6.0 
Pre-Installation package prior to updating the Version 6.0. For more information, see the 
To update a Defense Center:
1.
Read these release notes and complete any required pre-update tasks.
For more information, see 
.
2.
Download the update from the Support site:
for Series 3 and virtual Defense Centers:
Sourcefire_3D_Defense_Center_S3_Upgrade-5.4.1.2-38.sh
Note: 
Download the update directly from the Support site. If you transfer an update file by email, it may become 
corrupted.
3.
Upload the update to the Defense Center by selecting System > Updates, then clicking Upload Update on the 
Product Updates tab. Browse to the update and click Upload.
The update is uploaded to the Defense Center. The web interface shows the type of update you uploaded, its version 
number, and the date and time it was generated. The page also indicates whether a reboot is required as part of the 
update.
4.
Make sure that the appliances in your deployment are successfully communicating and that there are no issues 
reported by the health monitor.
5.
View the task queue (System > Monitoring > Task Status) to make sure that there are no tasks in progress.