Cisco Cisco AP541N Wireless Access Point 發佈版本通知
Cisco Small Business AP541N Access Point Release Notes for Versions 1.7.2 through 2.0.4
7
Release Notes
CSCtg28357—Error Message on MIB walk: Must Define the
apRadioStationIsolation Instance in CISCO-WLAN-ACCESS-POINT-MIB
apRadioStationIsolation Instance in CISCO-WLAN-ACCESS-POINT-MIB
The following MIBs are added in the MIB repository net-SNMP—
(C:\usr\share\snmp\mibs):
(C:\usr\share\snmp\mibs):
CISCO-WLAN-ACCESS-POINT-MIB.txt
CISCO-WLAN-ACCESS-POINT-REF-MIB-A-SKU.txt
CISCO-WLAN-ACCESS-POINT-REF-MIB-E-SKU.txt
CISCO-WLAN-ACCESS-POINT-REF-MIB-N-SKU.txt
CISCO-WLAN-ACCESS-POINT-REF-MIB-A-SKU.txt
CISCO-WLAN-ACCESS-POINT-REF-MIB-E-SKU.txt
CISCO-WLAN-ACCESS-POINT-REF-MIB-N-SKU.txt
The MIB names are C:\usr\etc\snmp (snmp.conf). For example:
mibdirs C:/usr/share/snmp/mibs
persistentDir C:/usr/snmp/persist
tempFilePattern C:/usr/temp/snmpdXXXXXX
mibs +OLD-CISCO-CHASSIS-MIB
mibs +CISCO-WLAN-ACCESS-POINT-REF-MIB
mibs +CISCO-WLAN-ACCESS-POINT-REF-MIB
mibs +CISCO-WLAN-ACCESS-POINT-REF-MIB
mibs +CISCO-WLAN-ACCESS-POINT-MIB
persistentDir C:/usr/snmp/persist
tempFilePattern C:/usr/temp/snmpdXXXXXX
mibs +OLD-CISCO-CHASSIS-MIB
mibs +CISCO-WLAN-ACCESS-POINT-REF-MIB
mibs +CISCO-WLAN-ACCESS-POINT-REF-MIB
mibs +CISCO-WLAN-ACCESS-POINT-REF-MIB
mibs +CISCO-WLAN-ACCESS-POINT-MIB
If there is anything wrong with the added MIBs, running a MIB walk at a command
prompt generates an error message. For example:
prompt generates an error message. For example:
C:\Documents and Settings\tdobrovo\Desktop>snmpwalk -v 2c -c public 172.25.144.155
sysObjectID
sysObjectID
Undefined OBJECT (apRadioStationIsolation): At line 3670 in C:/usr/share/
snmp/mibs/CISCO-WLAN-ACCESS-POINT-MIB.txt
SNMPv2-MIB::sysObjectID.0 = OID: CISCO-SMI::ciscoProducts.1135.1.28
snmp/mibs/CISCO-WLAN-ACCESS-POINT-MIB.txt
SNMPv2-MIB::sysObjectID.0 = OID: CISCO-SMI::ciscoProducts.1135.1.28
To avoid this error, define apRadioStationIsolation in
CISCO-WLAN-ACCESS-POINT-MIB.
CISCO-WLAN-ACCESS-POINT-MIB.
CSCtg28364—Standalone AP EDCA: Misreported Values for the TxOP Burst
Queue Attributes
Queue Attributes
The EDCA Max Burst parameter should be in units of 32us periods, but it is not
converted correctly by the access point.
converted correctly by the access point.
CSCtg28367—Cisco AP541N MIB sysObjectId Does Not Return the Correct
Number
Number
The wrong OID is returned by the object in the access point code.
CSCtg28374—CDP Show Neighbor Displays Only Four CDP Entries
When the
cdh show neighbor command is executed on console, it displays
only four neighbor entries.