Cisco Cisco Content Delivery Engine 250 安装指南
Fan2 Fan Speed 715 5273
Fan7 Fan Speed 715 5273
Power1 Fan 1 Speed 4007 7099
Power1 Fan 2 Speed 4007 10992
CPU1 Vcore Voltage 1.49 0.60 1.04
CPU2 Vcore Voltage 1.49 0.60 0.98
CPU1 VTT Voltage 1.34 0.92 1.14
CPU2 VTT Voltage 1.65 0.92 1.12
CPU1 DIMM Voltage 1.65 1.20 1.52
CPU2 DIMM Voltage 1.65 1.20 1.52
+1.5V Voltage 1.65 1.35 1.46
+1.8V Voltage 1.98 1.62 1.80
+5V Voltage 5.50 4.51 5.09
+12V Voltage 13.19 10.80 12.07
+1.1V Voltage 1.21 0.98 1.10
+3.3V Voltage 3.65 2.95 3.29
+3.3Vsb Voltage 3.65 2.95 3.24
VBAT Voltage 3.65 2.95 2.96
CPU1 Temperature 95/203 Low
CPU2 Temperature 95/203 Low
System Temperature 75/167 30/86
Power1 Temperature 75/167 34/93
Chassis Intrusion Good
Power Supply Failure Good
Power1 Supply Failure Good
Power2 Supply Failure Good
--------------------------------------------- Thu Jan 17 06:37:09 2013
Power1 Information: Type = AC Power, Firmware Rev = 6.0
Power2 Information: Type = Unknown
IPMI Information: Firmware Rev = 3.6
Note: Linux will usually strip the “0” from the 3.06 string.
2.3.4 Validation on VDS-IS (Pre-Release 3.2)
For systems running VDS-IS software prior to Release 3.2, the following signed script should be
executed to verify the IPMI firmware version.
executed to verify the IPMI firmware version.
The download location for this file is referenced
in the Field Notice.
#script execute showipmifw.sh.signed
IPMI Firmware Revision 3.6
IPMI Firmware Revision 3.6
Script showipmifw.sh.signed exited with return code 0
Note: Linux will usually strip the “0” from the 3.06 string.
In addition, please issue a “show tech” CLI command. As stated earlier, if the command
does not hang at the “system health” section (output from sdt), then the system booted
cleanly and should be free of any subsequent IPMI Watchdog issues.