Cisco Cisco Content Delivery Engine 250 Guida All'Installazione

Pagina di 14
 
 
Fan2 Fan Speed                              715       5273 
Fan7 Fan Speed                              715       5273 
Power1 Fan 1 Speed                         4007       7099 
Power1 Fan 2 Speed                         4007      10992 
CPU1 Vcore Voltage              1.49       0.60       1.04 
CPU2 Vcore Voltage              1.49       0.60       0.98 
CPU1 VTT Voltage                1.34       0.92       1.14 
CPU2 VTT Voltage                1.65       0.92       1.12 
CPU1 DIMM Voltage               1.65       1.20       1.52 
CPU2 DIMM Voltage               1.65       1.20       1.52 
+1.5V Voltage                   1.65       1.35       1.46 
+1.8V Voltage                   1.98       1.62       1.80 
+5V Voltage                     5.50       4.51       5.09 
+12V Voltage                   13.19      10.80      12.07 
+1.1V Voltage                   1.21       0.98       1.10 
+3.3V Voltage                   3.65       2.95       3.29 
+3.3Vsb Voltage                 3.65       2.95       3.24 
VBAT Voltage                    3.65       2.95       2.96   
CPU1 Temperature              95/203                   Low 
CPU2 Temperature              95/203                   Low 
System Temperature            75/167                 30/86 
Power1 Temperature            75/167                 34/93 
Chassis Intrusion                                     Good 
Power Supply Failure                                  Good 
Power1 Supply Failure                                 Good 
Power2 Supply Failure                                 Good 
--------------------------------------------- Thu Jan 17 06:37:09 2013  
Power1 Information: Type = AC Power, Firmware Rev = 6.0 
Power2 Information: Type = Unknown 
IPMI Information: Firmware Rev = 3.6 
Note: Linux will usually strip the “0” from the 3.06 string. 
2.3.4 Validation on VDS-IS (Pre-Release 3.2) 
For systems running VDS-IS software prior to Release 3.2, the following signed script should be 
executed to verify the IPMI firmware version.
   
The download location for this file is referenced 
in the Field Notice.     
 
#script execute showipmifw.sh.signed 
IPMI Firmware Revision 3.6 
 
Script showipmifw.sh.signed exited with return code 0 
Note: Linux will usually strip the “0” from the 3.06 string. 
 
In addition, please issue a “show tech” CLI command.    As stated earlier, if the command 
does not hang at the “system health” section (output from sdt), then the system booted 
cleanly and should be free of any subsequent IPMI Watchdog issues.