Cisco Cisco Workload Automation 6.3 用户指南

下载
页码 30
16
Configuring the UCS Manager Adapter
Defining a UCS Manager Connection
9.
In the UCS Manager User field, select the user account used to connect to UCS Manager.
10.
In the Port field, enter the appropriate port number for connecting to UCS Manager. Default is 80.
11.
If checked, HTTPS indicates SSL is to be used. Uncheck the checkbox if SSL is not to be used.
Note: 
During connection creation, when checked, the port will default to 80. (Default: unchecked )
12.
Click the Test button to test the connection.
13.
Click the Options tab to configure parameters for this connection.
The following parameters are available:
CONNECT_TIMEOUT – timeout in seconds establishing a connection (default 60)
REQUEST_TIMEOUT – timeout in seconds for API requests (default 60)
REQUEST_RETRIES – number of retries to retry a failed API request (default 3)
REFRESH_PERIOD – number of seconds between session refreshes. (default -1)
When a web client connects to UCS Manager, it needs to send refresh requests to UCS Manager to keep the web 
session active. This option specifies the maximum amount of time in seconds, allowed between refresh requests for 
a user in this domain. If not specified or specified with a value of <=0, indicates the default value configured in Cisco 
UCS should be used. This default is typically 600 seconds.
14.
Click OK to save the new USCM connection.
The configured connection displays in the Connections pane. See 
 for how to tell 
the status of a connection and troubleshoot issues.
Verifying Connection Status
The status light next to the connection indicates whether the CWA Master is connected to the USCM server. If the light 
is green, the USCM server is connected.
A red light indicates that the master cannot connect to the USCM server. USCM jobs will not be submitted without a 
connection to the USCM server. You can only define jobs from the Client if the connection light is green.
If the light is red, you can test the connection to determine the problem. Right-click the connection and select Test from 
the shortcut menu. A message displays on the Test USCManager Connection dialog describing the problem. Or go to 
Operator>Logs to look for error messages associated with this connection.
Connection Definition User Interface
You must create one or more USCM connections before CWA can run your USCM jobs. These connections also must be 
licensed before CWA can use them. A connection is created using the Connection Definition dialog and the user interface 
described here.
Connection Definition Dialog
The Connections Definition dialog contains the following elements:
Name—Enter a name for the Adapter.
Enabled—Activates or disables (deactivates) the connection, shutting down the adapter. A job cannot run on an 
adapter if its connection is disabled. If jobs try to run on a disabled connection, the job enters Agent Disabled status. 
Jobs already running on an agent that is disabled (or if the connection to the agent is lost) run to completion; 
however, their completion status is not returned until the agent is enabled.